Sony Professional BVU-900P Operation Manual page 8

Table of Contents

Advertisement

TRACKING
meter
Indicates the FM signal level for videohead-to-tape tracking.
AUDIO LEVEL meters
Indicate outgoing audio signal level.
AUDIO MONITOR selector
Selects the audio output to the HEADPHONES
jack @, MONITOR
connectors, and
AUDIO OUT MONITOR connectors.
CH-1: The audio signal on channel 1 is selected.
MIX: The audio signals on channels 1 and 2 are mixed and output to the MONITOR
and AUDIO OUT MONITOR
connectors. At the same time, they are separately
output to the HEADPHONES jack.
CH-2: The audio signal on channel 2 is selected.
4] REMOTEI/LOCAL selector
Use this selector when the BVU-900P is connected and operated with a VTR and the
other equipments.
This selector is activated when a VTR or other equipment is connected to the
REMOTE 1 connector (9-pin) on the connector panel.
The functions are controlled as follows:
REMOTE:
Set to this position when the BVU-900P is to be controlled by a VTR such
as BVU-950P or an automatic editing control unit connected via the REMOTE
1
connector (9-pin). With this selector set to REMOTE,
none of the function buttons
for tape travel, except for the STOP and EJECT buttons, will function.
LOCAL:
Set to this position to operate the BVU-900P alone.
e This selector is not activated when the REMOTE-1/REMOTE-2
selector on the sub-
control panel is set to REMOTE-2.
¢ The buttons available with this selector set to REMOTE can be specified in the dial
menu.
See "DIAL MENU OPERATION"
and the maintenance manual for details.
Indicating lamps
Each lamp lights as follows:
DOLBY NR:
Lights when a tape, which was recorded with Dolby NR on, is played
back.
TIME CODE:
Lights when the time code is reproduced.
TBC:
Lights when a video signal from the BKU-903A time base corrector (optional) is
output to the VIDEO OUT connectors located on the connector panel.
AUTO OFF:
Lights when moisture condenses on the head drum or when the tape
protector works.
SP: Lights when the BVU-900P plays back in the SP format. It does not light when a
tape, recorded in the conventional recording format, is being played back even if
is an SP cassette.
The SP lamp also lights while the BVU-900P is detecting the cassette type and
recorded signal format.
POWER switch
ON: Set to this position to turn on the power. The lamps for the TRACKING
meter ®
and the AUDIO LEVEL meters @ will light up. When the CTL/TC/DIAL MENU
selector ® is set to CTL, the time counter display indicates 0:00:00:00.
OFF:
Set to OFF to turn off the power.
7 (E)