Adjusting video and audio signal levels *
Monitoring audio signals
Video level adjustment
This is automatically adjusted.
Audio level adjustment
Time counter display
To monitor the audio signa! of the desired channel, use the AUDIO MONITOR
selector.
AUDIO
MONITOR
CH-1
~«——
To monitor the sound on CH-1
MIX
.
To monitor the sound on both CH-1
and CH-2 at the same time
CH-2
~*—— To monitor the sound on CH-2
A lap time, which is determined by counting the number of the pulses derived from
the recorded CTL signal with the CTL/TC/DIAL MENU selector on the control panel
set to CTL, is displayed.
Press the RESET button to reset the display to 0:00:00:00. The lap time from the reset
point to the beginning of the tape is displayed with a minus sign.
¢ Because the figures displayed depend on the number of the CTL pulses counted,
there may be errors in the displayed figures when a tape is played back with
missing CTL pulses.
e There may also be errors in the displayed figures when fast forward and rewind
operations are repeated because CTL signal read errors are likely to occur in those
modes.
¢ The displayed figures will not change when playing back a blank cassette tape
because it does not have the CTL signal recorded on it.