Excell SI-132 Service Manual page 41

High resolution weighing scale
Hide thumbs Also See for SI-132:
Table of Contents

Advertisement

EXCELL PRECISION CO., LTD
Customized Capacity Setting- How to Revise
To revise customized setting, please follow the steps below,
Press
key
TARE/ PT
According to
NOTE 4, re-key in
The parameters,
or do nothing
Press
key
TARE/ PT
According to NOTE 5,
Key in calibration
Weight value
Press
key
TARE/ PT
According to NOTE5,
Key in parameter
Press
key
TARE/ PT
According to NOTE6,
Key in parameter
Press
key
TARE/ PT
Continue to
do another
weight unit
revision, or
exit
customized
capacity
02005302
lb
.
lb
.
.
40
The display shows current setting
is max capacity of 12 lb with
0.005 lb/division for 2 seconds.
Display shows parameter settings
from last time.
For example:
5 ⇒ 5 weight UNITS are used
2 ⇒ "lb" as weight calibration unit
Display shows weight calibration UNITS
for 2 seconds:
⇒ " lb " calibration
⇒ " g "
⇒ " kg " calibration
For example:
019200 ⇒ 192.00 oz
Please enter weight calibration value in
proper UNITS value. For example:
12 lb = 192 oz
019200 ⇒ 192.00 oz
For example:
5 ⇒ division base value = 5
2 ⇒ 2 decimal points ⇒ division = 0.05 and
display as 0. _ 0.05
4 ⇒ "lb-oz "
0 ⇒ full segment range
3 ⇒ save into third UNITS slot
0 ⇒ multi-interval
The display shows the 3
unit has max capacity of 12 lb with
0.05 oz/division for 2 seconds, and
it returns to last screen
ON/ZERO key ⇒ Upward key (0~9 digit entry)
UNITS key ⇒ Downward key (0~9 digit entry)
TARE key ⇒ Move cursor rightward
NET/GROSS key ⇒ Move cursor leftward
calibration
rd
weight
ZSME300000237

Advertisement

Table of Contents
loading

Table of Contents