Remote connection
Remote connector — Connect a host device, such as a computer or touch
5
panel control, or a remote contact closure device to the switcher via this
9-pin D connector (figure 2-10) for remote control of the switcher.
See chapter 4, "Remote Control", for definitions of the SIS commands, details
on how to install and use the control software, and information on how to
construct a remote contact closure device.
5
1
Figure 2-10 — Remote port connector and pinout
Power connection
AC power connector — Plug a standard IEC power cord into this connector
6
to connect the switcher to a 100 VAC to 240 VAC, 50 or 60 Hz power source.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Pin
RS-232
1
1
—
2
TX
9
6
3
RX
Female
4
—
5
5
Gnd
6
—
7
—
6
9
Male
8
—
9
—
SW RGBHV Series Switchers • Installation
Contact closure
Function
In #1
Input #1
—
Transmit data (-)
—
Receive data (+)
In #2
Input #2
Gnd
Signal ground
In #3
Input #3
In #4
Input #4
In #5
Input #5
In #6
Input #6
2-9