Follett Champion 7 Installation Manual page 14

Ice and water dispenser with chewblet ice machine
Table of Contents

Advertisement

Initial Sanitizing Procedure (unit is not powered)
1. Complete the steps in the Access Internal Components section.
2. Remove cap from bin lid cover.
3. Screw bin lid cover cap onto ice discharge chute.
Note: On rear drain units, ensure that the pinch clamp is closed on the ice storage bin rear drain tube. On hot
tank units, ensure that the pinch clamp is closed.
4. Champion 7: mix 2.5 gal. (9.5 L) of water and 1 packet Kay-5 sanitizer.
Champion 15: mix 5 gal. (18.9 L) of water and 2 packets Kay-5 sanitizer.
5. Pour sanitizing solution into bin lid access spout until solution reaches the spout neck.
6. Allow the solution to remain in unit for 5 minutes.
7.
Drain system by opening pinch clamp and/or lowering drain tube.
8. Secure drain tube into holder.
9. Fill and drain twice with potable water. Secure drain tube.
10. Place a bucket under the dispense chute and remove cap. Note: Some sanitizing solution will remain and
drain out when cap is removed. Reposition cap on bin lid spout.
Note: On rear drain units, open the pinch clamp on the ice storage bin rear drain tube. On hot tank units,
open the pinch clamp.
Set Bypass Level on Internal Claris Filter Head
1. Use the provided water hardness test strips to determine and record the incoming water hardness.
Refer to the below table for appropriate bypass settings. The default bypass setting is 3
Hardness (ppm)
0
50
120
250
425
2. If the bypass setting needs to be adjusted, use the following procedure. If the bypass setting does NOT
need to be adjusted, proceed to flush the Claris filter.
3. Remove power from the unit.
4. Place a towel or pitcher under the Claris filter.
5. Ensure power is removed and/or unit is off.
6. Remove filter by turning counterclockwise and set aside filter.
Note: Place a towel or pitcher under filter to catch a small amount of water.
7.
Remove the two bracket screws so that the underside of the filter head can be accessed.
8. To adjust the bypass level, insert the bypass setting key into the underside of the filter head, press key
into filter head, and turn the bypass blending disc to the appropriate setting.
9. After positioning the bypass blending disc, remove and keep the bypass setting key.
10. Reinstall the bracket using the bracket screws.
11. Reinstall the Claris filter.
12. Reinstall front panel, ice dispense chute, and drip tray.
14
Champion Dispenser and Ice Machine - 115 V
Bypass
Filter Replacement Schedule
Setting
6
5
3
2
0
(month)
12
9
6
4
2
Gallons
1000
800
500
200