F80 Set Display Off Mode - SMC Networks PF3A701H Operation Manual

Digital flow switch
Hide thumbs Also See for PF3A701H:
Table of Contents

Advertisement

■[F80] Set display OFF mode
This function will turn the display OFF if no buttons are pressed for 30 seconds.
However when a flow monitor (PFG3 series) is connected, the displayed value might be different, due to an
error. When the flow monitor display is used, it is recommended to set this product to the display OFF
mode.
<Operation>
Display [F80] by pressing ▲ or ▼ button in function selection mode.
Select display OFF mode
Press the ▲ or ▼ button to select display OFF function.
: In display OFF mode, the under bar of sub display flashes.
: When any button is activated, the display will turn on. If no button operation is performed within
30 seconds, the display will turn off again.
Press the S button.
Press the S button to set.
[F80] Set display OFF mode completed.
Move on to select display OFF mode.
Return to function selection mode.
-53-