■[F80] Power saving mode
Power saving mode is selectable.
When selected and no buttons are pressed for 30 seconds, the pressure switch will shift to power saving
mode.
The default setting is normal mode (power saving mode off).
<Operation>
Press the
or
button in function selection mode to display [F80].
Setting of power saving mode
or
Press the
button to select power saving mode.
Power saving mode 1 remains enabled until turned off.
In power saving mode 1, the brightness of the whole display is reduced.
In power saving mode 2, when buttons are pressed the display is normal, but if no buttons are pressed for
30 seconds, it will revert to power saving mode. (Power saving is only enabled in measurement mode).
In power saving mode 2, a decimal point flashes and moves across the display.
(In saving mode 2, a decimal point flashes and modes across the display.)
Press the
button.
Press the
button to set.
Setting of [F80] Power saving mode completed.
Move on to setting of power saving mode.
Return to function selection mode.