■Piping
•Fit the raised part of the spacer to the recessed part (groove for the raised part) of the product.
•Tighten the retainer A with two hexagon socket head cap screws temporarily.
•Tighten the two hexagon socket head cap screws with a hexagonal wrench evenly.
Refer to the control items shown below for the tightening torque for the screws.
Control items
Applicable model
PF3A701H
PF3A702H
•The following options are required for coupling with modular F, R, and L combinations. They are separately
prepared by the user.
Digital flow switch
PF3A701H
PF3A702H
: For more information about the options, refer to our website (URL https://www.smcworld.com).
Hexagonal wrench socket size
Nominal value
3
Air combination
Spacer
AC30#-D
Y300-D
AC40#-D
Y400-D
-17-
Tightening torque
1.2±0.05 N・m
Spacer with bracket
Y300T-D
Y400T-D
No.PF※※-OMX0007-B
Pipe adapter
E300-#03-D
E400-#04-D