■Piping

●Piping specification: -02 and -N02
After hand tightening, tighten the fitting using a spanner on the flat surfaces of the fitting.
The tightening torque must be 8 to 12 N•m.
●Piping specification: -F02
After hand tightening, tighten the fitting using a spanner on the flat surfaces of the fitting.
The tightening torque must be 4 to 5 N•m.
When tightening, do not hold the upper part of the product (Display) with a spanner.