Image 4–14
Reinstall the UV blocker assembly and the side cover in case you do not intend to install another
xenon lamp immediately in the Lamp House.
CAUTION: Expired xenon lamps.
Dispose of expired bulbs that are beyond warranty according the national regulations. See also
related user manual of the lamp supplier for more guidance.
CAUTION: Small amounts of radioactive material (< 1000 Bq per lamp) are deliberately added to
Xenon lamps for functional reasons. These lamps are manufactured under regulatory control as
consumer product according to IAEA basic safety standard BSS 115. Disposal according to national
regulations is required e.g. in Europe covered by WEEE regulation. See also related user manual of
the lamp supplier for more guidance.
When returning a xenon lamp for warranty adjustment, pack it in its original shipping container.
Complete and return all required warranty information.
4.5 Installation of the xenon lamp in manual S/M
Lamp House
WARNING: DO NOT PERMIT UNAUTHORIZED PERSONNEL TO PERFORM OR ATTEMPT ANY
PHASE OF XENON LAMP HANDLING OR SERVICE. ONLY TRAINED AND QUALIFIED
TECHNICAL SERVICE PERSONNEL ARE ALLOWED TO HANDLE THE XENON LAMP.
WARNING: This procedure may only be performed by qualified technical service personnel.
CAUTION: Xenon compact arc lamps are highly pressurized. When ignited, the normal operating
temperature of the bulb increases the pressure to a level at which the bulb may explode if not
handled in strict accordance to the manufacturer's instructions. The bulb is stable at room
temperature, but may still explode if dropped or otherwise mishandled. Whenever the lamp house,
containing a xenon lamp, has to be dismantled or whenever the protective container or cloth has to
be removed from the xenon lamp, authorized protective clothing MUST be worn!
WARNING: Always wear face protection (full face shield) when handling xenon lamps.
WARNING: Always wear protective clothing (welder's jacket) when handling xenon lamps.
9