Perkins 4008-30 Operation And Maintenance Manual page 32

Industrial engines
Hide thumbs Also See for 4008-30:
Table of Contents

Advertisement

32
SEBU9077-02
Operation Section
Engine Storage
i03781209
Engine Storage
Refer to Perkins Engine Company Limited, Stafford,
ST16 3UB for information on engine storage.
There are three different levels of engine storage.
Level "A, B and C" .
Level " " A " "
Level "A" will give protection for 12 months for diesel
engines and for gas engines. This level is used for
engines that are transported in a container or by a
truck.
Level " " B " "
This level is additional to level "A" . Level "B " will give
protection under normal conditions of storage from
−15° to +55°C (5° to 99°F) and "90%" relative
humidity, for a maximum of 2 year.
Level " " C " "
This level is additional to level "B" . Level "C" will give
protection for five years in tropical or in arctic
climates. Level "C" also meets MOD NES 724 Level
"J" for Europe, when engines are stored in an
unheated building or in the open under a waterproof
cover.

Advertisement

Table of Contents
loading

This manual is also suitable for:

4006-23

Table of Contents