No.
Part
2. Attachment
6
Compressor
(continued)
1) Carry out installation by following reverse procedure in
the detachment 1) to 4).
2) Install the compressor and braze the pipes, and then
install each wire around the compressor.
(Comp.lead, Case heater, Temperature sensor (TD, TK))
Exchange a comp. leads together as replacing a
compressors.
* The right fig. shows caution when the comp. leads
are installed (For models with strap terminals screw
fixation of comp. lead)).
• Incorporate the terminal block into the compressor.
• Bend each terminal at 90°while holding the terminal
block so that it does not tilt.
• To prevent the screws from being slanted, place the
comp.leads in the specified position as shown in the
figure, and then tighten the screw according to the
following steps.
(1) Temporary tightening the screws by your hand.
(2) Tighten the screws securely with an electric
(3) Tighten them with the specified torque using a
* Do not screw the screws slantingly.
• Insert the comp.leads into the sealing material, and
attach the terminal cover so that they do not pinch
with the terminal cover, and then draw out the
comp.leads straightly.
• Do not apply excessive stress to the comp.leads.
• Do not put the protective tubes in the terminal cover.
• Note that the leads do not touch the comp. shell.
3) Wrap the soundproof material*1 around the
compressor and install the compressor cover
*2.(Fig. 30 to 32)
*1 Wrap the soundproof material around the compressor
so that its bottom is put on the legs of the compressor.
*2 Install the commpressor cover so that pipes or wires
around the comp. do not deform or are caught with the
cover.
<Standard 6,8 ton>
<High heat 6 ton>
(soundproof material)
Wrap it clockwise.
Three legs
Fig. 30
Work procedure
screwdriver.
torque wrench driver. (1.8 ft•Ibs (2.5N•m))
Otherwise, the comp.leads may burn.
<Standard 10 ton>
(soundproof material)
Wrap it clockwise.
Three legs
Fig. 31
460V models (6~16ton)
208-230V
Standard 6~10ton
High heat 6ton
208-230V
Standard 12~14ton
High heat 8, 10ton
Black
White
When removing the comp lead, it is a
good idea to mark which comp lead
you removed it from.
<Standard 12,14 ton>
<High heat 8,10 ton>
(soundproof material)
Wrap it counterclockwise
Four legs
Fig. 32
- 319 -
Remarks
White
Black
Red
Draw out the comp
leads straight.
Black
Red
White
Draw out the comp
leads straight.
Draw out the comp
leads straight.
Red
Red
<Standard 10,16 ton>
(soundproof material)
Wrap it clockwise.
Three legs x 2 units
Fig. 33
Black
White
Red
Black
White

Advertisement