Download Print this page

Riello RESIDENCE HM Series Instructions For The User page 20

Hide thumbs Also See for RESIDENCE HM Series:

Advertisement

INSTALLER PARAMETERS
MENU
PARAMETER
P2
COMBUSTION
P201
GAS - GAS TYPE
P205
d52 - P1 GAS VALVE
P206
GAC - VALVE CALIBRATION
P208
APL - POWER
P3
CONFIGURATION
P301
HYDRAULIC CONFIGURATION
P306
MIN FAN SPEED
P307
MAX FAN SPEED
P309
MAX FAN SPEED HTG
P310
RANGE RATED
P311
CONFIG AUX 1
P312
EXHAUST PROBE RESET
P4
HEATING
P405
PUMP CONTROL TYPE
P408
OT CASCADE CONTROL
SCREED FUNCTION
P409
P410
ANTI CYCLE FUNCTION
P411
RESET CH TIMERS
P415
MAIN ZONE TYPE
P416
MAX CH SET
P417
MIN CH SET
P418
WEATHER COMP ENABLE
P419
WEATHER COMP CURVE
P420
NIGHT COMPENSATION
P421
CH CLOCK ENABLE
P422
MODE SELECTION
P433
BUILDING TYPE
P434
OUTDOOR REACTIVITY
HT = HIGH TEMPERATURE
P5
DHW
P508
MIN DHW SET
P509
MAX DHW SET
P511
DHW ENHANCED FUNCTION
SERVICE PARAMETERS
MENU
PARAMETER
P3
CONFIGURATION
P302
WATER PRESSURE TRANSDUCER
P303
AUTO-FILL ENABLE
P304
BEGIN SYSTEM FILLING
P305
AIR PURGING CYCLE
P4
HEATING
P401
HYST OFF HIGH TEMP
P402
HYST ON HIGH TEMP
P403
HYST OFF LOW TEMP
P404
HYST ON LOW TEMP
P5
DHW
P510
DHW DELAY
P512
CH DELAY POST-DHW
P513
CH DELAY TIME
P7
SERVICE
P701
ENABLE ALARM LOG
P706
CALL SERVICE FUNCTION
P707
SERVICE EXPIRY
P708
HIGH EFFICIENCY ENABLE
P8
CONNECTIVITY
P801
BUS 485 CONFIG
P803
OT CONFIG
0 = HEATING ONLY - 1 = INSTANTANEOUS WITH FLOWSWITCH - 2 = INSTANTANEOUS WITH FLOWMETER - 3 =
Min
1
20
0
0 (25kW)
0
1000 rpm
3700 rpm
P306 (MIN FAN SPEED)
0
0
41
0
0min
0
0
MIN CH SET
20°C
0
HT: 1.0 - LT: 0.2
0
0
0
5
0
LT = LOW TEMPERATURE
37°C
49°C
0
Min
0
0
0
2°C
2°C
2°C
2°C
0 sec
0
1 sec
0
0
0
0
0
0
Value
Password level
Max
4
70
1
1 (35kW)
4
3600 rpm
10000 rpm
P307
(MAX FAN SPEED)
DO NOT CHANGE
2
1
100
NOT USED ON THIS MODEL
1
if boiler in OFF and
30min
1
1
HT: 80°C - LT: 45°C
MAX CH SET
1
if outdoor temperature
HT: 3.0 - LT: 0.8
only if P418 = 1
1
1
1
20
only if P418 = 1
255
49°C
60°C
5
Value
Password level
Max
1
1
NOT AVAILABLE ON THIS MODEL
1
10°C
10°C
10°C
10°C
60 sec
1
255 sec
1
2
255
1
2
1
20
Factory setting
INSTALLER
1
INSTALLER
45
if boiler in OFF
INSTALLER
0
INSTALLER
0
INSTALLER
2*
refer to the technical
INSTALLER
data table
refer to the technical
INSTALLER
data table
refer to the technical
INSTALLER
data table
INSTALLER
0
INSTALLER
0
INSTALLER
85
INSTALLER
0
LT systems
INSTALLER
3min
INSTALLER
0
INSTALLER
0
INSTALLER
HT: 80°C - LT: 45°C
INSTALLER
HT: 40°C - LT: 20°C
INSTALLER
0
sensor present
HT 2.0 - LT 0.5
INSTALLER
0
0
0
5
INSTALLER
20
INSTALLER
37°C
INSTALLER
60°C
INSTALLER
0
Factory setting
SERVICE
1
SERVICE
0
SERVICE
1
SERVICE
5°C
SERVICE
5°C
SERVICE
3°C
SERVICE
3°C
SERVICE
0 sec
SERVICE
0
SERVICE
6 sec
0
(the value automatically
SERVICE
switches to 1 after 2
hours of operation)
SERVICE
2
SERVICE
52
SERVICE
0
SERVICE
0
SERVICE
1
Customised
values
Customised
values
- 4 = STORAGE

Advertisement

loading