Wasp WWS800 Reference Manual

Wasp WWS800 Reference Manual

Wasp wws800: reference guide
Hide thumbs Also See for WWS800:

Advertisement

Table of Contents

Restore Default Settings ............................................1
Exit Setup without Changes......................................1
Set Connection ...........................................................1
RF Auto Shutdown Duration....................................1
Memory Mode Parameters .......................................2
List Setting..................................................................3
Buzzer Settings ...........................................................3
Reading Redundancy Setting....................................4
Scan Mode Setting .....................................................4
Auto-Sense Setting .....................................................4
Scanner Time-out Duration ......................................5
Negative Barcode Setting ..........................................5
Delay between Reread ...............................................5
Keyboard Wedge Parameters...................................6
Laptop Support..........................................................8
RS-232 Parameters ....................................................9
Bluetooth Serial Port Parameters...........................11
Prefix / Postfix Settings............................................12
Character Substitution ............................................12
Code ID Selection.....................................................12
Code ID Setting ........................................................13
Length Code Setting (2 digits) ................................14
Select Readable Codes .............................................17
Code39 Parameters..................................................22
Italy Pharmacode Parameters ................................22
French Pharmacode Parameters ............................23
Industrial 25 Parameters.........................................23
Interleave 25 Parameters ........................................24
Matrix 25 Parameters..............................................26
Codabar Parameters................................................27
Plessey Parameters ..................................................28
Telepen Parameters .................................................28
MSI Parameters .......................................................29
MSI Parameters .......................................................29
EAN128 Parameters ................................................30
EAN8 Parameters ....................................................31
UPCA Parameters....................................................31
UPCE Parameters....................................................32
EAN13 Parameters ..................................................33
RSS Code ID Selection ............................................34
RSS14 Parameters ...................................................34
RSS Limited Parameters.........................................35
RSS Limited Parameters ........................................ 35
Activate Editing Formats........................................ 36
Editing Format Parameters.................................... 37
Decimal Digits .......................................................... 49
Hexadecimal Digits.................................................. 50
RS-232 Character Table ......................................... 51

Advertisement

Table of Contents
loading

Summary of Contents for Wasp WWS800

  • Page 1: Table Of Contents

    Memory Mode Parameters ...2 List Setting...3 Buzzer Settings ...3 Reading Redundancy Setting...4 Scan Mode Setting ...4 Auto-Sense Setting ...4 Scanner Time-out Duration ...5 Negative Barcode Setting ...5 Delay between Reread ...5 Keyboard Wedge Parameters...6 Laptop Support...8 RS-232 Parameters ...9 Bluetooth Serial Port Parameters...11 Prefix / Postfix Settings...12...
  • Page 2: Restore Default Settings

    Exit Setup without Changes Set Connection Programming Instructions : (1) Read the label. (2) Read the Serial Number barcode on the bottom of the desired WWS800 Base Station within 5 seconds to complete this setting. RF Auto Shutdown Duration Programming Instructions : (1) Read the label. (2) Program the desired auto shutdown duration (in minutes) by reading Decimal Digits on page 49.
  • Page 3: List Setting

    List Setting Page1 Page 2 Page 3 Page 4 Page 5 Buzzer Settings < Buzzer Enable> • Buzzer Frequency 8 kHz 2 kHz Update Reading Redundancy Setting Page 6 Page 7 Scan Mode Setting Page 8 Page 9 Page 10 Buzzer Disable Auto-Sense Setting <...
  • Page 4: Scanner Time-Out Duration

    Scanner Time-out Duration Programming Instructions : (1) Read the label. (2) Program the desired time-out duration by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. Negative Barcode Setting Enable...
  • Page 5: Laptop Support

    • Keyboard Alphabets Layout < Default Layout > QWERTZ • Keyboard Digits Layout < Default Layout > Upper Row • Keyboard Capital Lock Type < Default > Capital Lock • Capital Lock Setting Capital Lock ON < Capital Lock OFF > Auto Detection Update AZERTY...
  • Page 6: Rs-232 Parameters

    Programming Instructions : (1) Read the label. (2) Program the desired inter- < 9600 > character delay by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting. 2400 < None > Scanner Ready Data Ready INV. Data Ready Enter Setup...
  • Page 7: Bluetooth Serial Port Parameters

    Bluetooth Serial Port Parameters • Activate BlueTooth Serial Port Interface • Device Name Broadcasting < Yes > • Authentication • PIN Code Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits.
  • Page 8: Code Id Setting

    Code ID Setting Code 39 * French Pharmacode * Interleave 25 * Codabar * UPCE * EAN13 * Code 128 * Plessey * Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits.
  • Page 9 • Matrix 25 Length Code Enable • Codabar Length Code Enable • UPCA Length Code Enable • UPCE Length Code Enable • EAN8 Length Code Enable • EAN13 Length Code Enable Update < Disable > < Disable > < Disable > <...
  • Page 10: Select Readable Codes

    Select Readable Codes • Code 39 < Enable > • Italy Pharmacode Enable • French Pharmacode Enable • Industrial 25 < Enable > • Interleave 25 < Enable > Update Disable < Disable > < Disable > Disable Disable • Matrix 25 Enable •...
  • Page 11 • Plessey Enable • Telepen Enable • UPCA < Enable No Addon > Disable No Addon Enable Addon2 < Disable Addon2 > Enable Addon5 < Disable Addon5 > Update < Disable > < Disable > • UPCE < Enable No Addon > Disable No Addon Enable Addon2 <...
  • Page 12: Code39 Parameters

    • EAN13 < Enable No Addon > Disable No Addon Enable Addon2 < Disable Addon2 > Enable Addon5 < Disable Addon5 > RSS14 Enable • RSS Limited Enable • RSS Expanded Enable Update Code39 Parameters < Disable > < Disable > Italy Pharmacode Parameters <...
  • Page 13: French Pharmacode Parameters

    French Pharmacode Parameters • Checksum Transmission < Enable > Industrial 25 Parameters • Start / Stop Selection < Industrial 25 > Matrix 25 • Checksum Verification Enable • Checksum Transmission < Enable > Update Disable Interleave 25 Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 49.
  • Page 14: Matrix 25 Parameters

    • Checksum Verification Enable • Checksum Transmission < Enable > • Max / Min Code Length Qualification Select Max / Min Length Qualification Max Length * Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting.
  • Page 15: Codabar Parameters

    • Max / Min Code Length Qualification Select Max / Min Length Qualification Max Length * • Fixed Code Length Qualification Select Fixed Length Qualification Fixed Length 1 * Programming Instructions : (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 49.
  • Page 16: Msi Parameters

    MSI Parameters • Checksum Verification < Single Modulo 10 > Modulo 11 & 10 • Checksum Transmission < Last digit not Transmitted > Last 2 Digits not Transmitted • Max / Min Code Length Qualification Select Max / Min Length Qualification Max Length * Programming Instructions : (1) Read the label.
  • Page 17: Ean8 Parameters

    EAN8 Parameters • Convert to EAN13 Enable • Checksum Transmission < Enable > UPCA Parameters • Convert to EAN13 < Enable > • System Number Transmission < Enable > • Checksum Transmission < Enable > Update UPCE Parameters < Disable > Disable Disable Disable...
  • Page 18: Ean13 Parameters

    EAN13 Parameters • ISBN Conversion Enable • ISSN Conversion Enable • Checksum Transmission < Enable > Update RSS Code ID Selection < Disable > RSS14 Parameters < Disable > Disable • Code ID Transmission < Enable > • Application ID Transmission <...
  • Page 19: Rss Limited Parameters

    RSS Limited Parameters • Code ID Transmission < Enable > • Application ID Transmission < Enable > • Checksum Transmission < Enable > RSS Limited Parameters • Code ID Transmission < Enable > Update Activate Editing Formats • Format 1 Disable •...
  • Page 20: Editing Format Parameters

    Editing Format Parameters • Format Selection Format 1 Format 3 • Restore Default Format Update • Applicable Data Length Programming Instructions : (1) Read the label. (2) Program the desired length by Format 2 reading Decimal Digits on page 49. (3) Read the “Validate” label (also on page 49) to complete this setting.
  • Page 21 • Total Number of Fields Update • Applicable Code Type Clear Code 39 Italy Pharmacode French Pharmacode Industrial 25 Interleave 25 Matrix 25 Codebar Code 93 Code 128 EAN128 / RSS UPCE No Addon UPCE Addon2 UPCE Addon5 EAN8 No Addon EAN8 Addon2 EAN8 Addon5 End of Format Programming...
  • Page 22 • Field1 Setting Divide Field by EAN13 No Addon Field Terminating String EAN13 Addon2 EAN13 Addon5 Field Terminating String * Programming Instructions : (1) Read the label. (2) Program the desired character UPCA No Addon string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits.
  • Page 23 • Field2 Setting Divide Field by Field Terminating String Field Terminating String * Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting.
  • Page 24 • Field4 Setting Divide Field by Field Terminating String Field Terminating String * Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 50) to complete this setting.
  • Page 25 • Additional Fields Setting Additional Field 1 * Additional Field 2 * Additional Field 3 * Programming Instructions : (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 50. One character consists of 2 hexadecimal digits.
  • Page 26: Decimal Digits

    Decimal Digits • Validate Update Hexadecimal Digits • Validate Enter Setup...
  • Page 27: Rs-232 Character Table

    RS-232 Character Table DLE SP " ENQ NAK % ACK SYN & < > Keyboard Wedge Character Table ‘ " 3 Home 6 Down & Left B Right C PgUp Exec < D Enter E PgDn > Update Enter Setup...

Table of Contents