LIGHTING AND SHUTTING DOWN PILOTS

Open Top, Griddle Top, and Hot Top
1. Turn the main gas supply ON.
2. Turn all top burner valves to ON to purge gas line of air. (Length of time to purge air will vary.)
3. Turn top burner valve knobs to OFF.
4. Wait 30 seconds.
5. Using a taper, light the pilot(s).
6. If pilot fails to light, wait 5 minutes and repeat Steps 1 through 5.
Nightly Shutdown: Turn burner valve OFF; pilot will remain lit.
Complete Shutdown: Turn burner valve OFF; pilot will remain lit. Turn main gas valve OFF.
Standard Oven - "S" Model (Fig. 2)
1. Turn Thermostat and Shut-Off Valve to the OFF position.
2. Wait 5 minutes.
3. Remove lower panel to locate pilot cutout.
4. Using a taper, light oven pilot by depressing the red ignition button located
on the side control panel below the thermostat knob.
5. Continue to hold down Red Button for at least 30 seconds.
6. When Red Button is released, Pilot should remain lit.
7. Turn Shut-Off Valve to the ON position and turn the Thermostat to the desired
temperature.
8. Replace lower panel.
9. If pilot flame becomes extinguished or does not light, repeat Steps 1 through 6.
Nightly Shutdown: Turn Thermostat to OFF; pilot will remain lit.
Complete Shutdown: Turn Thermostat and Shut-Off Valve to OFF. Turn main gas valve OFF.
Convection Oven - "C" Model (Fig. 3)
1. Connect range to main electrical supply.
2. Turn Thermostat and Shut-Off Valve to the OFF position.
3. Turn Fan Switch to OFF position.
4. Wait 5 minutes.
5. Remove lower panel to locate pilot cut out.
6. Using a taper, light oven pilot by depressing the red ignition button located
on the side control panel above the Shut-Off Valve.
7. Continue to hold down the Red Button for at least 30 seconds.
8. When Red Button is released, Pilot should remain lit.
9. Turn Shut-Off Valve to the ON position and turn the Thermostat to the desired
setting.
10. Replace lower panel.
11. If pilot flame becomes extinguished or does not light, repeat Steps 1 through 8.
Nightly Shutdown: Turn Thermostat to OFF; pilot will remain lit.
Complete Shutdown: Turn the Thermostat, Shut-Off Valve, and Fan Switch to OFF. Turn
main gas valve OFF.
— 10 —
RED BUTTON
(SAFETY)
THERMOSTAT
DIAL
SHUT-OFF
VALVE
FIG 2
RED BUTTON
(SAFETY)
SHUT-OFF
VALVE
THERMOSTAT
DIAL
FAN
SWITCH
FIG 3