Computer Control (Vc4Gc/Vc6Gc) - Vulcan-Hart VC4GC Service Manual

Vc4g & vc6g series full size gas convection ovens
Hide thumbs Also See for VC4GC:
Table of Contents

Advertisement

FULL SIZE GAS CONVECTION OVENS - SERVICE PROCEDURES AND ADJUSTMENTS
B.
If doors operate properly, continue with
procedure.
7.
Install the lower front cover.
COMPUTER CONTROL
(VC4GC/VC6GC)
Operation
Refer to the Instructions Manual for specific
operating instructions.
Setup Mode
NOTE: Use the setup mode to verify that the control
is configured to the factory settings which result in
the proper operation of the oven. If the CAL1
parameter is other than zero, determine if it is still
needed before resetting to zero. See COMPUTER
CONTROL CALIBRATION (VC4GC/VC6CG).
Changing the C_F, InP1, rL1 & rH1
parameters will default all menus.
1.
Use this key sequence to access the setup
mode.
Up arrow; Rack 1; Temperature; Temperature;
Down arrow; Rack 1
2.
Once in the setup mode the display will
alternate between the parameter and
programmed data.
To change data to the factory setting, use
the arrow keys.
To select the next parameter, press the
Rack 1 key.
After the last Parameter and Data is
viewed, press the Rack 1 key a final time
to exit the setup mode and return to
operations mode. The current set point
temperature will be displayed.
After 1 minute of no key activations, the
control will return to operation mode.
3.
Listed are the parameters and data you should
find.
F24682 (Rev. B, October 2007)
MENU
Celsius_Fahrenheit
Guard Band
Temperature
Compensation
Input Type 1
Range Low 1
Range High 1
Hysteresis
Calibration Offset
Exit Setup Mode and
return to Operation
Mode.
Probe Test
1.
Set the control to 350EF.
2.
Access the back of the control panel to
disconnect the probe lead wires.
3.
Install a jumper wire across the probe terminals.
This will simulate room temperature.
A.
If the heat light comes on and the actual
temperature is room temperature, replace
the probe.
B.
If the heat light does not come on or the
actual temperature is not room
temperature, replace the control.
Solid State Relay Test
1.
Remove the right side panel as outlined under
COVERS AND PANELS.
2.
Set the temperature to 350°F or high enough to
keep the heat ON for several minutes.
3.
Check for +5 VDC on input side of SSR
(terminals 3 & 4).
A.
If +5 VDC is present, continue to step 4.
B.
If no voltage is present, computer control is
not functioning properly.
4.
Check for 120 VAC at load side of SSR
(terminals 1 & 2).
A.
If no voltage is present, solid state relay is
not functioning properly.
1)
B.
If 120 VAC is present, component is
functioning properly.
Page 28 of 68
ALTERNATING ON
DISPLAY
PARAMETER
C_F
gb
tcnP
InP1
rL1
rH1
HYS1
CAL1
set point temperature is
displayed or if call for
heat, dashes (----)
displayed.
Replace the SSR and check for
proper operation.
DATA
F
4000
OFF
J
75
500
3
0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vc4gdVc4gsVc6gcVc6gdVc6gs

Table of Contents