Cisco Firepower 9300 Hardware Installation Manual page 80

Hide thumbs Also See for Firepower 9300:
Table of Contents

Advertisement

Remove and Replace the Fan Module
Note
The chassis is designed to have all fan modules in place and operating at all times. Do not leave the fan module
bay empty for longer than is necessary to replace it with a new fan module.
Step 1
To remove a fan module, face the rear of the chassis, and hold the handle of the fan module.
Step 2
Press down on the spring latch at the top of the fan module.
Step 3
Pull the fan module out of the chassis.
Figure 50: Remove and Replace the Fan Module
Step 4
To install a new fan module, hold the fan module with the spring latch at the top of the module.
Step 5
Push the fan module into the chassis until it is properly seated and the spring latch snaps into place.
If the system is powered on, listen for the fans. You should immediately hear the fans operating. If you do not hear the
fans, make sure the fan module is inserted completely into the chassis and the faceplate is flush with the outside surface
of the chassis.
Step 6
Verify that the fan is operational by checking the fan module LED. It takes about a minute for the Fan LED to be updated.
See
Fan Modules, on page 28
Cisco Firepower 9300 Hardware Installation Guide
76
for a description of the fan module LEDs.
Installation, Maintenance, and Upgrade

Advertisement

Table of Contents
loading

Table of Contents