Table 1 (Page 2 of 3). Extended Communications Test SRCs
SRC
Test Level
Instructions
610007
ALL
The test sequence ran without detecting any failure. Do the following:
LEVELS
1. Write down the SRC and test-level digit that appear on the screen.
2.
Exit the test mode as follows:
Set the control unit power switch to off (0) .
Set the control unit Test switch to Off .
Make sure that your modem or DCE is set up for normal opera-
ti on.
Make sure that the communications cable is attached to the
modem or DCE and that all three switches are in the OPER posi-
ti on.
Set the control unit power switch to on (I) .
3. If you ran the extended test because of an 004X or 005X SRC, locate
that SRC in the IBM 5394 Remote Control Unit Operator's Guide and
Problem Determination Procedures and follow the recovery proce-
dure given there.
4. If you ran the extended test because you could not establish commu-
nications with the host system and no SRC appeared on the screen,
take the action corresponding to the test-level digit that you recorded
in step 1 on page 14:
If test level is 3, report to the host system operator that a com-
munications problem exists. The problem does not appear to be
in the control unit.
If test level is 4, report to the host system operator that:
-
A communications problem exists.
-
The problem does not appear to be in the control unit.
-
The local loopback test passed.
-
Remote loopback is not possible for this configuration.
If test level is 6, report to the host system operator that:
-
A communications problem exists.
-
The problem does not appear to be in the control unit.
-
The local loopback test passed.
-
The remote loopback test passed.
14
V.35
Supplement RPO
800725
and RPO
800726