Jenn-Air JFX2897DRM Service Manual page 31

Four door bottom mount
Hide thumbs Also See for JFX2897DRM:
Table of Contents

Advertisement

FROM
TO
VOLTAGE
P1-1
P1-2
CONSTANT 115 VAC
P1
115 VAC
P1-3
P1-4
CONSTANT 115 VAC
P2-1
P2-4
CONSTANT 14 VDC
P2
P2-2
P2-5
14 VDC
CONSTANT 14 VDC
P2-3
P2-6
CONSTANT 14 VDC
P1-1
P1-2
CONSTANT 115 VAC
P1
115 VAC
P1-2
P1-4
CONDENSER FAN SERVICE TEST 4. 115 VAC, IF CONDENSER FAN ON.
P2-1
P1-2
RC OR FC DOOE OPEN = 115 V. DOORS CLOSED = 0 V.
P2-2
P1-2
AIR BAFFLE FEEDBACK. SERVICE TEST 3, STEP 3.
P2-3
P1-2
FC DEFROST HEATER OUTPUT, BI-METAL BYPASS. SERVICE TEST 6. 115 V, IF BI-METAL
CLOSED.
P2
115 VAC
P2-4
P1-2
WATER FILTER REMOVED = 115 V. WATER FILTER INSTALLED = 0 V.
P2-5
P1-2
AIR BAFFLE OUTPUT. SERVICE TEST 3, STEP 3.
P2-6
P1-2
FILL TUBE/FASCIA/PANTRY HEATER OUTPUT. SERVICE TEST 19. 01 = 115 V, 02 = 0 V.
P2-7
P1-2
FC DEFROST HEATER OUTPUT WITH BI-METAL. SERVICE TEST 6. 115 V.
P3-1
P2-1
RC OR FC DOOR OPEN = 115 V. DOORS CLOSED = 0 V.
P3-3
P1-2
ICE MAKER WATER VALVE. SERVICE TEST 25. DIGIT 1 = 1 = 115 V (WATER VALVE ON)
115 VAC
P3
P3-4
P1-2
WATER DISPENSING VALVE. SERVICE TEST 25. DIGIT 2 = 1 = 115 V.
P3-5
P1-2
LEFT RC DOOR MUST BE CLOSED = 115 V. OPEN = 0 V.
P3-7
P3-8
130 VDC
AUGER OUTPUT. LH RC DOOR CLOSED. ACTIVATE ICE PADDLE = 130 - 140 VDC.
P4-1
P4-4
14 VDC
CONSTANT 14 VDC.
P4
P4-3
COMMUNICATION
P5-1
P5-2
RC THERMISTOR OUTPUT = 1.5 - 5 VDC.
P5
5 VDC
P5-3
P5-4
FC THERMISTOR OUTPUT = 1.5 - 5 VDC.
P7-1
P7-2
5 VDC
ICE MAKER THERMISTOR OUTPUT = 1.5 - 5 VDC MAXIMUM.
P7
P7-5
P7-6
14 VDC
ICE MAKER MOTOR OUTPUT. PRESS SW3 TO ACTIVATE TEST 57. UP TO 2 MINUTES DELAY.
P8-1
P8-2
ICE BIN THERMISTOR OUTPUT= 1.5 - 5 VDC.
5 VDC
P8-5
ICE BOX FAN PWM CONNECTION.
P8
P8-3
P8-4
RC EVAPORATOR THERMISTOR OUTPUT = 1.5 - 5 VDC.
P8-7
P8-8
3-6 VDC
INVERTER OUTPUT 3-6 VDC WHEN COMPRESSOR IS RUNNING.*
P9
P9-2
P9-3
12 VDC
SHELF LIGHTING OUTPUT.
P12-4
P1-2
PANTRY HEATER OUTPUT. SERVICE TEST 73. 01 = 115 VAC.
P12
115 VAC
P12-6
P1-2
ICE MAKER HEATER OUTPUT. SERVICE TEST 58. DIGIT 1 = 1 = HEATER ON (115 V).
P13-1
P13-2
3 WAY REFRIGERANT VALVE, CANNOT CHECK VOLTAGE OUTPUT.
P13
P13-3
P13-4
3 WAY REFRIGERANT VALVE, CANNOT CHECK VOLTAGE OUTPUT.
P14-1
P14-2
FC FAN MOTOR OUTPUT. SERVICE TEST 3, STEP 2.
P14
P14-3
P14-4
14 VDC
RC FAN MOTOR OUTPUT. SERVICE TEST 3, STEP 3.
P14-7
P14-6
CONSTANT 14 VDC.
For Service Technician Use Only
CONDITIONS
FROM
TO
VOLTAGE
J1-1
J1-3
14 VDC
CONSTANT 14 VDC.
J1-2
COMMUNICATION
J1-5
J1
REFER TO SERVICE TEST 15 FOR VERIFYING THE EMITTER/RECEIVER BOARDS.
J1A-4
J1A-1
14 VDC
CONSTANT 14 VDC.
J1A
J1A-2
COMMUNICATION
J3A-1
J3A-3
14 VDC
LED OUTPUT = 14 VDC, WHEN TURNED ON.
J3A
J3A-2
J3A-4
5 VDC
PANTRY THERMISTOR OUTPUT = 1.5 - 5 VDC.
J1-1
J1-2
0 VDC WHEN WATER DISPENSER PAD IS PRESSED. 14 VDC WHEN RELEASED.
J1
J1-1
J1-3
14 VDC
ICE DISPENSER PAD IS PRESSED*, (IF J1-3 USED).
J1-2
J1-3
ICE DISPENSER PAD IS PRESSED*, (IF J1-3 USED).
J2-1
J2-8
FLIPPER MULLION HEATER. SERVICE TEST 35. PRESS SW3 = 14VDC.
J2-4
J2-6
CONSTANT 14 VDC.
J2-7
J2-11
ICE DOOR STEPPER MOTOR IS ACTIVE* (IF USED).
J2
14 VDC
J2-7
J2-12
ICE DOOR STEPPER MOTOR IS ACTIVE* (IF USED).
J2-7
J2-13
ICE DOOR STEPPER MOTOR IS ACTIVE* (IF USED).
J2-7
J2-14
ICE DOOR STEPPER MOTOR IS ACTIVE* (IF USED).
J3-1
J3-2
0 VDC WHEN WATER DISPENSER PAD IS PRESSED. 14 VDC WHEN RELEASED.
J3
J3-1
J3-3
14 VDC
WATER DISPENSER PAD IS PRESSED* (IF J3-3 USED).
J3-2
J3-3
WATER DISPENSER PAD IS PRESSED* (IF J3-3 USED).
J5-1
J5-3
14 VDC
CONSTANT 14 VDC.
J5
J5-2
COMMUNICATION
J6
J6-1
J6-3
14 VDC
DISPENSER LIGHT ON.
P1-1
P1-4
P1
P1-3
COMMUNICATION
P3-1
P3-2
CAVITY LIGHT (POINT LED'S) OUTPUT.
P3
P3-3
P3-4
CAVITY LIGHT (POINT LED'S) OUTPUT.
*Pulsing DC signal. May not be read with all meters.
COMPONENT TESTING
CONDITIONS
NOT USED.
Four Door Bottom Mount