Polaris Patriot 650 2024 Owner's Manual page 213

Table of Contents

Advertisement

DIAGNOSTIC TROUBLE CODES (DTCS) – LEFT
HAND CONTROLS
MATRYX LEFT HAND CONTROLS – DIAGNOSTIC TROUBLE CODES (DTCS)
SPN = SUSPECT PARAMETER NUMBER / FMI = FAILURE MODE INDICATOR
SPN
FMI
0
5
516360
6
31
0
5
516361
6
DIAGNOSTIC TROUBLE CODES (DTC)
P-CO-
DESCRIPTION
DE
C1106
Left Grip Heater
Driver Over Temp
C1107
Left Grip Heater
Driver Under
Current
C1108
Left Grip Heater
Driver Over
Current
C1109
Left Grip Heater
Driver Internal
Short
C110A
Right Grip Heater
Driver Over Temp
C110B
Right Grip Heater
Driver Under
Current
C110C
Right Grip Heater
Driver Over
Current
FAULT SETTING
The temperature at
left grip heater driver
is greater than 60
DegC for 5 seconds
The current at left
grip heater driver is
is less than 1A for 5
seconds
The current at left
grip heater driver is
is greater than 7A for
5 seconds
An internal short has
been detected at the
left grip heater driver.
This would result in a
100% duty cycle
output when not
expected.
The temperature at
right grip heater
driver is greater than
60 DegC for 5
seconds
The current at right
grip heater driver is
is less than 1A for 5
seconds
The current at right
grip heater driver is
is greater than 7A for
5 seconds
FAULT
HEALING
The temperature
at left grip heater
driver is less
than 60 DegC for
5 seconds
The current at
left grip heater
driver is is
greater than
1.5A for 5
seconds
The current at
left grip heater
driver is is less
than 6A for 5
seconds
An internal short
is not detected at
the left grip
heater driver.
The temperature
at right grip
heater driver is
less than 60
DegC for 5
seconds
The current at
right grip heater
driver is is
greater than
1.5A for 5
seconds
The current at
right grip heater
driver is is less
than 6A for 5
seconds
211