Installation
instructions
Use only for short
run installations
No. of 900
Rigid
Rigid
Elbows
Metal
Metal
O
56 Feet
42 Feet
i
48 Feet
34 Feet
2
40 Feet
26 Feet
3
32 Feet
18 Feet
24" DRYER EXHAUST LENGTH
RECOMMENDED
MAXIMUM
LENGTH
Exhaust Hood Types
Recommended
Use only for short
run installations
No. of 900
Rigid
Rigid
Elbows
Metal
Metal
O
45 Feet
56 Feet
i
53 Feet
26 Feet
2
24 Feet
16 Feet
EXHAUST INFORMATION
(CONT.)
27" DRYER EXHAUSTLENGTH
RECOMMENDED
MAXIMUM
LENGTH
Exhaust Hood Types
Recommended
, For every extra 90° elbow, reduce the allowable vent
system length by 10 ft.
, Two 45° elbows will be treated like one 90° elbow. For the
side exhaust installations,add one 90° elbow to the chart.
, The total vent system length includes all the straight
portions and elbows of the system (transition duct
included).
EXHAUST SYSTEM CHECK LIST
HOOD OR WALL CAP
, Terminate in a manner to prevent back drafts or entry
of birds or other wildlife.
, Termination should present minimal resistance to
the exhaust air flow and should require little or no
maintenance to prevent clogging.
, Never install u screen in or over the exhaust duct. This
could cause lint build up.
, Wall cups must be installed at least 12 in. above ground
level or any other obstruction with the opening pointed
down.
SEPARATION OF TURNS
For best performance, separate all turns by at least 4
ft. of straight duct, including distance between lust turn
and exhaust hood.
TURNS OTHERTHAN 90 °
, One turn of 450 or less may be ignored.
, Two 450 turns should be treated us one 900 turn.
, Each turn over 450 should be treated us one 900 turn.
SEALING OF JOINTS
, Alljoints should be tight to avoid leaks. The mule end of
each section of duct must point away from the dryer.
, Do not assemble the ductwork with fasteners that
extend into the duct. They will serve as a collection
point for lint.
, Duct joints can be made air and moisture-tight
by
wrapping the overlapped joints with duct tape.
, Horizontal runs should slope down toward the outdoors
1/4 inch per foot
INSULATION
Duct work that runs through an unheated urea or is
near air conditioning should be insulated to reduce
condensation and lint build-up.
P-J EXHAUST CONNECTION
, WARNING
- TO REDUCE THE
RISK OF FIRE OR PERSONAL INJURY:
, This apliancce must be exhausted to the outdoors.
, Use only 4" rigid metal ducting for the home exhaust
duct.
, Use only 4" rigid metal or UL-listed flexible metal
(semi-rigid or foil-type) duct to connect the dryer
to the home exhaust duct. It must be installed
in accordance
with
the
instructions
found
in
"Connecting The Dryer To House Vent" on page 8 of
this manual.
, Donot terminate exhaust in u chimney, u wall, u ceiling,
gas vent, crawl space, attic, under an enclosed floor,
or in any other concealed space of u building. The
accumulated lint could create a potential fire hazard.
, Never terminate the exhaust into a common duct
with u kitchen exhaust system. A combination
of
grease and lint creates mpotential fire hazard.
, Do not use duct longer than specified in the exhaust
length table. Longer ducts can accumulate
lint,
creating u potential fire hazard.
, Never install u screen in or over the exhaust duct. This
will cause lint to accumulate, creating mpotential fire
hazard.
, Do not assemble ductwork with any fasteners that
extend into the duct. These fasteners can accumulate
lint, creating mpotential fire hazard.
, Do not obstruct incoming or exhausted air.
, Provide an access for inspection and cleaning of
the exhaust system, especially at turns and joints.
Exhaust system shall be inspected and cleaned at
least once year.
THIS DRYER COMES READY FOR REAR
EXHAUSTING.
IF SPACE IS LIMITED, USE
THE INSTRUCTIONS
IN SECTION
9 TO
EXHAUST DIRECTLY FROM THE SIDES OR
BOTTOM OF THE CABINET.
EXTERNAL DUCT
OPENING
CSA (AGA} APPROVED
NEW FLEXIBLE
GAS
For straight
line installation,
connect
LINE CONNECTOR the drger exhaust to the external
exhaust hood using duct tape or
GAS
damp.
INLET
PIPE
DUCTTAPEOR
DUCTCLAMP
4" METALDUCTCUT
TO PROPER LENGTH
DUCTTAPEOR
DUCTCLAMP