Toner Density Control; Overview - Ricoh AFICIO A267 Service Manual

Hide thumbs Also See for AFICIO A267:
Table of Contents

Advertisement

DEVELOPMENT

2.6.6 TONER DENSITY CONTROL

Overview

There are four modes for controlling toner supply as shown in the following tables.
The mode can be changed with by SP2-921. The factory setting is sensor control 1
mode.
Basically, toner density is controlled using the standard TD sensor voltage (Vts),
toner supply reference voltage (Vref), actual TD sensor output voltage (Vt), and ID
sensor output data (Vsp/Vsg).
Toner Supply Clutch On Time
TD Sensor Output
(Vt)
Vt Reference
Voltage (Vref)
Vt Reference
Voltage Update
ID Sensor Output
(Vsp/Vsg)
TD Sensor Initial
Setting (Vts)
2-46
20 September 1999
Calculation
New Vref
Vref Update
A265D517.WMF