Ricoh AFICIO A267 Service Manual page 271

Hide thumbs Also See for AFICIO A267:
Table of Contents

Advertisement

FUSING/EXIT
20 September 1999
6.5.3 THERMOFUSE
[A]
A267R507.WMF
[B]
[B]
[C]
[D]
A267R504.WMF
1. Remove the fusing unit. (See Fusing Unit.)
2. Remove the fusing upper cover [A] (4 screws).
3. Remove the pressure springs [B].
4. Remove the hot roller stripper bracket [C] (3 screws).
5. Replace the thermofuse [D] (2 screws).
6-18