Installation - Crestron Multimedia Presentation System 250 MPS-250 Operation Manual

Multimedia presentation system
Table of Contents

Advertisement

Multimedia Presentation System 250
QM Network Topology
Origination Points
MPS-250
MPS-250
Ventilation
Rack Mounting
24 • Multimedia Presentation System 250: MPS-250
QM
QM- MD7x2
QM

Installation

The MPS-250 should be used in a well-ventilated area. The venting holes should not
be obstructed under any circumstances.
To prevent overheating, do not operate this product in an area that exceeds the
environmental temperature range listed in the table of specifications. Consider using
forced air ventilation and/or incrementing the spacing between units to reduce
overheating. Consideration must be given if installed in a closed or multi-unit rack
assembly since the operating ambient temperature of the environment may be greater
than the room ambient temperature. Contact with thermal insulating materials should
be avoided on all sides of the unit.
The MPS-250 can be mounted in a rack or stacked with other equipment. Two
"ears" are provided with the MPS-250 so that the unit can be rack mounted. These
ears must be installed prior to mounting. Complete the following procedure to attach
the ears to the unit. The only tool required is a #2 Phillips screwdriver.
WARNING: To prevent bodily injury when mounting or servicing this unit in a
rack, take special precautions to ensure that the system remains stable. The following
guidelines are provided to ensure your safety:
When mounting this unit in a partially filled rack, load the rack from the
bottom to the top with the heaviest component at the bottom of the rack.
If the rack is provided with stabilizing devices, install the stabilizers before
mounting or servicing the unit in the rack.
NOTE: If rack mounting is not required, rubber feet are provided for tabletop
mounting or stacking. Apply the feet near the corner edges on the underside of the
unit. For additional information, refer to "Stacking" on page 25.
NOTE: Reliable earthing of rack-mounted equipment should be maintained.
Particular attention should be given to supply connections other than direct
connections to the branch circuit (e.g. use of power strips).
To install the ears:
1. There are screws that secure each side of the MPS-250 top cover. Using a
#2 Phillips screwdriver, remove the three screws closest to the front panel
from one side of the unit. Refer to the diagram following step 3 for a
detailed view.
Midpoints
QM
MPS-250
Operations Guide – DOC. 6647A
Crestron MPS-250
Endpoints
QM
TPS-12G/15G-QM-L