Sleep 1 is Sleep mode 1, in Cool modes: sleep sta-
tus after run for one hour, the main unit setting tem-
perature will increase 1 , two hours, setting temper-
ature increased 2 , then the unit will run at this set-
ting temperature; In Heat mode: sleep status after
run for one hour, the setting temperature will de-
crease 1 , two hours, setting temperature will de-
crease 2 , then the unit will run at this setting tem-
perature.
Sleep 2 is sleep mode 2, that is air conditioner will
run according to the presetting a group of sleep tem-
perature curve.
Sleep 3 the sleep curve setting under Sleep mode
by DIY;
(1) Under Sleep 3 mode, press "Health" button for a
long time, remote controller enters into user indivi-
duation sleep setting status, at this time, the time
of remote controller will display "1HOUR", the set-
ting temperature "88" will display the correspond-
ing temperature of last setting sleep curve and blink
(The first entering will display according to the initial
curve setting value of original factory);
(2) Adjust " + " and " - " button, could change the
corresponding setting temperature, after adjusted,
press "Health" button for confirmation;
(3) At this time, 1hour will be automatically increas-
ed at the timer position on the remote control, (that
are "2HOUR" or "3HOUR" or "8HOUR"), the place of
setting temperature "88" will display the corres-
ponding temperature of last setting sleep curve
and blink;
(4) Repeat the above step (2)~(3) operation, until
8 hours temperature setting finished, sleep,curve
setting finished, at this time, the remote controller
will resume the original timer display; temperature
display will resume to original setting temperature.
Sleep 3 the sleep curve setting under Sleep mode
by DIY could be inquired:
The user could accord to sleep curve setting method
to inquire the presetting sleep curve, enter into user
individuation sleep setting status, but do not
change the temperature, press "Health" button
directly for confirmation. Note: In the above presetting
or enquiry procedure, if continuously within 10s,
there is no button pressed, the sleep curve setting
within 10s, there is no button pressed, the sleep
curve setting status will be automatically quit and
resume to display the original displaying. In the
presetting or enquiry procedure, press " On/Off " button,
"Mode" button, "Timer" button or "Sleep" button,
the sleep curve setting or enquiry status will quit
similarly.
Light button
Press this button to control the LED status on the
displayer, the circulation change is as follow:
no display
LED on
When selecting "
controller, LED indicator on indoor unit will adjust
the luminance automatically according to the
ambient intensity of illumination.
Function introduction for
combination buttons
Energy-saving function
Under cooling mode, press "Mode" and "Timer"
buttons simultaneously to start up or turn off ener-
gy-saving function. When energy-saving function
is started up, "SE" will be shown on remote con-
troller, and air conditioner will adjust the set tem-
perature automatically according to ex-factory
setting to reach to the best energy-saving effect.
Press "Mode" and "Timer" buttons simultaneously
again to exit energy-saving function.
NOTE
Under energy-saving function, fan speed is defaulted
at auto speed and it can't be adjusted.
Under energy-saving function, set temperature can't
be adjusted.
Sleep function and energy-saving function can't oper-
ate at the same time. If energy-saving function has
been set under cool mode, press "Sleep" button will
cancel energy-saving function. If sleep function has
been set under cool mode, start up the energy-saving
function will cancel sleep function.
Child lock function
Hold " On/Off " and " - " buttons simultaneously for
3s to turn on or turn off child lock function. When
child lock function is on, "
remote controller. If you operate the remote con-
troller, the "
sending signal to the unit.
Temperature display switchover function
Under OFF status, hold "Mode" and " - " buttons
simultaneously for 3s to switch temperature
displaybetween °C and °F.
function
function is for limiting power of the whole unit.
Press "Mode" and "Sleep" buttons simultaneously,
18
LED off
Auto LED
" (Auto LED) with remote
" icon is displayed on
" icon will blink three times without
no display
LED off