Lenovo ThinkSystem SR670 Reference Manual page 97

Hide thumbs Also See for ThinkSystem SR670:
Table of Contents

Advertisement

• FQXSPPW0008I: [PowerSupplyElementName] has been turned off.
This message is for the use case when an implementation has detected a Power Unit that has been
Disabled.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Power Off
SNMP Trap ID: 23
CIM Prefix: PLAT CIM ID: 0106
User Action:
Information only; no action is required
• FQXSPPW0009I: [PowerSupplyElementName] has been Power Cycled.
This message is for the use case when an implementation has detected a Power Unit that has been power
cycled.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0108
User Action:
Information only; no action is required
• FQXSPPW0031J: Numeric sensor [NumericSensorElementName] going low (lower non-critical) has
asserted.
This message is for the use case when an implementation has detected a Lower Non-critical sensor going
low has asserted.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Voltage
SNMP Trap ID: 13
CIM Prefix: PLAT CIM ID: 0476
User Action:
CMOS battery is recommended to replace with new one.
• FQXSPPW0035M: Numeric sensor [NumericSensorElementName] going low (lower critical) has
asserted.
This message is for the use case when an implementation has detected a Lower Critical sensor going low
has asserted.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Voltage
SNMP Trap ID: 1
CIM Prefix: PLAT CIM ID: 0480
.
Chapter 2
XClarity Controller events
93

Advertisement

Table of Contents
loading

This manual is also suitable for:

7y367y377y38

Table of Contents