Lenovo ThinkSystem SR670 Reference Manual page 161

Hide thumbs Also See for ThinkSystem SR670:
Table of Contents

Advertisement

b. Check for "Remaining Life" of spare blocks on the XCC Web GUI.
2. Back up data.
3. Check if the DCPMM meets warranty terms.
a. If the DCPMM meets the warranty terms, contact Lenovo Support for DCPMM replacement.
b. If the DCPMM does not meet the warranty terms, order a new comparable DCPMM through an
authorized Lenovo reseller.
4. Collect Service log and contact Lenovo support to schedule DCPMM replacement.(Note: Unless
otherwise specified in other agreements or contract terms, parts beyond their warranty terms and/or
parts that have reached their maximum usage limitations do not qualify for warranty service.)
• FQXSFMA0032M: Intel Optane DCPMM [arg1] has no remaining spares block.
Severity: Error
User Action:
Complete the following steps:
1. Back up data.
2. Check the current Intel Optane DCPMM DIMM health status in one of the following ways:
a. Run DCPMM test under LXPM diagnostic. Look for "Percentage Remaining" of spare blocks.
b. Check for "Remaining Life" of spare blocks on the XCC Web GUI.
3. Check if the DCPMM meets warranty terms.
a. If the DCPMM meets the warranty terms, contact Lenovo Support for DCPMM replacement.
b. If the DCPMM does not meet the warranty terms, order a new comparable DCPMM through an
authorized Lenovo reseller.
4. Collect Service log and contact Lenovo support to schedule DCPMM replacement.(Note: Unless
otherwise specified in other agreements or contract terms, parts beyond their warranty terms and/or
parts that have reached their maximum usage limitations do not qualify for warranty service.)
• FQXSFMA0033M: Intel Optane DCPMM persistent memory interleave set has [arg1] DCPMMs
(DIMM [arg2]), [arg3] DIMMs' location is not correct.
Severity: Warning
User Action:
Complete the following steps:
1. Collect XCC Service Data.
2. Power off system.
3. The following error message FQXSFMA0034M logs will provide the correct location for DCPMMs.
4. Move all DCPMMs of error message FQXSFMA0034M logs to the correct location.
5. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0034M: DIMM [arg1] (UID: [arg2]) of Intel Optane DCPMM persistent memory interleave
set should be moved to DIMM slot [arg3] in sequence.
Severity: Warning
User Action:
Complete the following steps:
1. Collect XCC Service Data.
2. Power off system.
.
157
Chapter 3
UEFI events

Advertisement

Table of Contents
loading

This manual is also suitable for:

7y367y377y38

Table of Contents