• FQXSPIO0014J: Bus [SensorElementName] is operating in a degraded state.
This message is for the use case when an implementation has detected a Bus is Degraded.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Other
SNMP Trap ID: 60
CIM Prefix: PLAT CIM ID: 0246
User Action:
Complete the following steps until the problem is solved:
1. Check the PCI LED.
2. Reseat the affected adapters and riser card.
3. Update the server firmware (UEFI and BMC) and adapter firmware.
4. Note: Some cluster solutions require specific code levels or coordinated code updates. If the device
is part of a cluster solution, verify that the latest level of code is supported for the cluster solution
before you update the code.
5. Make sure that the adapter is supported. For a list of supported optional devices, see http://www.
ibm.com/systems/info/x86servers/serverproven/compat/us/.
6. Remove both adapters.
7. Replace the PCIe adapters.
8. Replace the riser card.
• FQXSPIO0015M: Fault in slot [PhysicalConnectorSystemElementName] on system
[ComputerSystemElementName].
This message is for the use case when an implementation has detected a Fault in a slot.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0330
User Action:
Complete the following steps to fix the error:
1. Make sure that all I/O expansion adapters have correct and matching levels of device drivers and
firmware.
2. Check the event log of XClarity Controller for additional information about failing components. Check
http://support.lenovo.com/ for TECH tips or firmware updates that might correct the error.
3. If there are no entries related to the error in the event log, contact Lenovo support
• FQXSPIO2001I: The connector [PhysicalConnectorElementName] configuration error has been
repaired.
This message is for the use case when an implementation has detected an Interconnect Configuration
was Repaired.
Severity: Info
Serviceable: No
Automatically notify Support: No
.