Faults
Increased play at
clutch lever.
After actuating the
clutch lever, the
clutch does not dis‐
engage / engage.
SIMOGEAR electric monorail gearbox
Operating Instructions, 01/2024, A5E53220855A/RS-AA
Causes
Clutch lever has become loose.
After engagement, the clutch is out of
mesh.
Clutch has been displaced.
Faults, causes and remedies
Remedy
Tighten fastening nut at clutch lever.
Turn the output shaft until the clutch
engages.
Call Technical Support. Clutch must be
readjusted or serviced.