Advertisement

4.5.2

Painted version

The corrosion protection system is classified according to the corrosiveness categories in
DIN EN ISO 12944‑2.
Paint according to corrosiveness categories
Paint system
Corrosiveness category C1, unpainted for gearbox and motor housings made of aluminum
-
Paint system
Corrosiveness category C1 for normal environmental stress
1‑component hydro paint, top coat
Paint system
Corrosiveness category C2 for low environmental stress
2‑component - polyurethane top coat
SIMOGEAR electric monorail gearbox
Operating Instructions, 01/2024, A5E53220855A/RS-AA
Description
Indoor installation
Heated buildings with neutral atmospheres
Resistance to greases and some resistance to mineral
oils, aliphatic solvents
Standard
Description
Indoor installation
Heated buildings with neutral atmospheres
Resistance to greases and some resistance to mineral
oils, aliphatic solvents
Standard paint for gearbox housings made of cast iron
Description
Indoor and outdoor installation
Unheated buildings with condensation, production
areas with low humidity, e.g. warehouses and sports
facilities
Atmospheres with low levels of pollution, frequently
rural areas
Resistance to greases, mineral oils and sulfuric
acid (10 %), caustic soda (10 %) and is conditionally
resistant to aliphatic solvents
Technical description
4.5 Surface treatment
31