Uc (Used Cell) Counter Maximum Threshold Value Register; (00D0H, 00D4H, 00D8H, 00Dch, 00E0H, 00E8H) - NEC mPD98410 User Manual

1.2g atm switch lsi
Table of Contents

Advertisement

4.3.30 UC (Used Cell) counter maximum threshold value register (00D0h, 00D4h, 00D8h, 00DCh, 00E0h, 00E8h)
Register name
Address
UCthCBR
00D0h
UCthRVR
00D4h
UCthRM
00D8h
UCthNVR
00DCh
UCthABR
00E0h
UCthUBR
00E8h
15
14
13
These registers set the upper-limit threshold value of the Used Cell Counter in each class. If a cell in each class is
congested in the cell buffer, exceeding the corresponding threshold value, the cell is discarded.
Field
Bit
UCthCBR
bit [15:7]
UCthRVR
bit [15:7]
UCthRM
bit [15:7]
UCthNVR
bit [15:7]
CHAPTER 4 INTERNAL REGISTERS
Default
0000_0000_0xxx_xxxx
0000_0000_0xxx_xxxx
0000_0000_0xxx_xxxx
0000_0000_0xxx_xxxx
0000_0000_0xxx_xxxx
0000_0000_0xxx_xxxx
12
11
10
9
8
UCthCBR
UCthRVR
UCthRM
UCthNVR
UCthABR
UCthUBR
R/W
R/W
0000_0000_0 to 1111_1111_1: Upper-limit threshold value in CBR
R/W
0000_0000_0 to 1111_1111_1: Upper-limit threshold value in
R/W
0000_0000_0 to 1111_1111_1: Upper-limit threshold value in RM
R/W
0000_0000_0 to 1111_1111_1: Upper-limit threshold value in
R/W
R/W
R/W
R/W
R/W
R/W
R/W
7
6
5
4
3
Function
class
(128-cell units: 0/128/256/ ... /65408)
rtVBR class
(128-cell units: 0/128/256/ ... /65408)
class
(128-cell units: 0/128/256/ ... /65408)
nrtVBR class
(128-cell units: 0/128/256/ ... /65408)
2
1
0
Default Value
0000_0000_0
(0000h)
0000_0000_0
(0000h)
0000_0000_0
(0000h)
0000_0000_0
(0000h)
165