-40 °C to 40 °C
 
The table below shows the assignment of the SFP transceivers to the specified groups.
Category
SFP
SFP+
6.7

Signaling contact

The signaling contact is an event-driven or manually controlled failsafe alarm relay. Individual
alarms can be configured to trigger the relay when the associated event occurs. The relay can
also be fixed in an open or closed state.
Manually controlling the relay may be useful to:
• Verify the failsafe relay is properly connected following the installation of the device
• Verify the open/close state is caused by the device itself or some other hardware
• Keep the relay in an open/close state while troubleshooting a network issue
SCALANCE XR-500
Operating Instructions, 07/2023, C79000-G8976-C692-01
24 x SFP, Group 1
Max. 2 of the SFP transceivers used in Group B can be from
SFP Group 2.
Group
Group 1
Group 2
Group 1
Group 2
8 x SFP, Group 1
or
8 x SFP+, Group 1
Max. 2 of the SFP
transceivers used in
Group C can be from
SFP Group 2.
Type
SFP991-1
SFP991-1 (C)
SFP991-1LD
SFP992-1
SFP992-1LD
SFP992-1LD (C)
SFP991-1LH+
SFP991-1ELH200
SFP992-1+
SFP992-1LD+
SFP992-1LH
SFP992-1LH+
SFP992-1ELH
SFP992-1BXMT
SFP992-1BXMR
SFP992-1BX10T
SFP992-1BX10R
SFP993-1
SFP993-1LD
SFP993-1LH
Connecting up
6.7 Signaling contact
2 x RJ45
ports
10 Gbps
 
Article number
6GK5 991-1AD00-8AA0
6GK5 991-1AD00-8FA0
6GK5 991-1AF00-8AA0
6GK5 992-1AL00-8AA0
6GK5 992-1AM00-8AA0
6GK5 992-1AM00-8FA0
6GK5 991-1AE00-8AA0
6GK5 991-1AE30-8AA0
6GK5 992-1AG00-8AA0
6GK5 992-1AM30-8AA0
6GK5 992-1AN00-8AA0
6GK5 992-1AP00-8AA0
6GK5 992-1AQ00-8AA0
6GK5 992-1AL00-8TA0
6GK5 992-1AL00-8RA0
6GK5 992-1AM00-8TA0
6GK5 992-1AM00-8RA0
6GK5 993-1AT00-8AA0
6GK5 993-1AU00-8AA0
6GK5 993-1AV00-8AA0