Technical specifications
Plate thickness
Bending radii
Surface of the housing
Mean time between failure (MTBF)
MTBF (EN/IEC 61709; 40 °C)
1)
Wiring rules
Note the wiring rules (Page 65).
Ambient temperature with SFP
2)
The maximum ambient temperature during operation depends on the operating elevation
and the installed plug-in transceivers, see also the section "SFP plug-in transceiver (Page 36)"
in the "Accessories" section.
Restriction when operating with plug-in transceivers of this type
3)
A maximum of two plug-in transceivers of this type may be used.
Derating
4)
The derating values depend on the maximum ambient temperatures during operation up to
2000 m.
Degree of protection
5)
The IP20 degree of protection was not examined in the context of UL certification.
9.4

SCALANCE XR526-8

9.4.1
24 V AC/DC device version
The following technical specifications apply to the 24 V AC/DC version of the SCALANCE XR526-8.
Technical specifications
Connection to Industrial Ethernet
Electrical connectors
Slots for plug-in transceiver
(SFP+)
Diagnostics interface
SCALANCE XR-500
Operating Instructions, 07/2023, C79000-G8976-C692-01
1.5 mm
1.5 mm
Stainless steel X6CR17
> 8.3 years
Quantity
Connector
Transmission speed
Properties
Quantity
Connector
Transmission speed
24
RJ45 jack
10 / 100 / 1000 Mbps
Half/full duplex, MDI‑X pinning
8
SFP/ SFP+ plug-in transceiver
1 / 10 Gbps
Technical specifications
9.4 SCALANCE XR526-8
2
RJ45 jack
1 / 2.5 / 5 / 10 Gbps
109