Siemens SCALANCE XR-500 Operating Instructions Manual page 104

Simatic net industrial ethernet switches
Hide thumbs Also See for SCALANCE XR-500:
Table of Contents

Advertisement

Technical specifications
9.3 SCALANCE XR524-8WG
Technical specifications
Slots for plug-in transceiver
(SFP+)
Diagnostics interface
Serial interface
Button
Configuration interface
Removable data storage medium Quantity
Connection to power supply
Power supply
1)
Current consumption
Effective power loss
Cable cross-section
Permitted ambient conditions
104
Quantity
Connector
Transmission speed
Quantity
Connector
Quantity
Product name
Design
Rated voltage
Voltage range
Frequency
Frequency range
Fusing
Properties
Degree of pollution
Rated voltage
Rated voltage
Minimum
Maximum
8
SFP/ SFP+ plug-in transceiver
1 / 10 Gbps
1
USB Type B
1
1
Siemens Configuration and License PLUG (CLP)
Spring-loaded terminal block, 2-pin
24 V AC / 24 V DC
19.2 to 30.0 V AC
19.2 to 31.2 V DC
50 / 60 Hz (with AC)
50 Hz to 60 Hz
10 A / 250 V
Implemented redundantly;
The connected power supply must meet the require‐
ments of NEC Class 2 or PS2/LPS in compliance with
UL 62368-1.
2
3 A
72 W
0.75 mm^2 (AWG 18)
2.5 mm^2 (AWG 12)
Operating Instructions, 07/2023, C79000-G8976-C692-01