WARNING
Pay attention (conformity) to phase and neutral allocation of house connection and
appliance (connection schemes); otherwise, components can be damaged.
Warranty does not cover damage resulting from improper installation.
WARNING
If the supply cord is damaged, it must be replaced by the manufacturer, its service
1N ~ (32A)
01
02
04
06
03
05
L
N
2N ~ (16A): Separate the 2-phase wires
01
02
03
05
07
04
06
L1
L2
N
2 x 1N ~ (16A): Separate the wires before
01
04
02
05
07
03
06
L1
N1
L2
N2
WARNING
For correct supply connection, follow the wiring diagram attached near the terminals.
01
220-240 V ~
04
Blue
02
Brown
05
Gray
03
Black
06
Green/Yellow
(L1 and L2) before connection.
01
220-240 V ~
05
Blue
02
380-415 V ~
06
Gray
03
Brown
07
Green/Yellow
04
Black
connection.
01
220-240 V ~
05
Black
02
Brown
06
Gray
03
Blue
07
Green/Yellow
04
220-240 V ~

Installing into the work surface

Make a note of the serial number on the
appliance rating label prior to installation.
This number will be required in the case
of requests for service and is no longer
A
accessible after installation, as it is on the
original rating plate on the upperside or
underside of the appliance.
A.
Serial number
NOTE
Pay special attention to the minimum space and clearance requirements.
NOTE
The bottom of the hob is equipped with a fan. If there is a drawer under the hob
it should not be used to store small objects or paper, since they could damage the
fan or interfere with the cooling if they are sucked into it.
03
01
02
NOTE
No.
Explanation
Size
01
Height of
Min. 2 mm
ventilation hole
Width of
560 mm
02
ventilation hole
Distance between
03
Min. 50 mm
end of appliance
and side wall of
work surface