Toshiba RAS-24J2KVG-UA Service Manual page 97

Table of Contents

Advertisement

No.
Part name
Vertical louver
1) Follow the procedure item 3 and 8 .
9
assembly
2) Remove 2 fixing screws from the base
10
Bearing base
<Caution at assembling>
Cross flow fan
1) Follow the procedure item 9 and
11
2) Loosen the set screw of the cross flow fan.
3) Lift up the heat exchanger follow the figure.
<To re-installation>
1) To incorporate the fan motor and the motor
Procedures
vertical louver then remove the vertical louver
assembly from the body back.
1) Follow the procedure item 3 .
2) Remove 4 fixing screws from the bearing
base, then remove it from the main unit.
- - If the bearing is out from the housing, push it
into the specified position, then incorporate it
in the main unit.
Pull out the left hand side until the cross flow
fan released from the shaft of the fan motor
and then pull out the lower side of heat
exchanger follow the figure.
into the position in the following figure.
- Install the cross flow fan so that the right
end of the 1st joint from the right of the
Cross flow fan is keep 3.5mm from closed
wall of the main unit.
Cross flow fan
3.5 mm
Set screw
- Holding the set screw, install the
cross flow fan so that flat area on shaft of
the fan motor comes to the mounting hole
of the set screw.
Bearing base
Bearing
.
10
Body back
Fan motor
- 97 -
FILE NO. SVM-19002
Remarks
Vertical louver
Screw
Heat exchanger
Bearing base
Cross flow fan
Cross flow fan
Vertical louver Hexagon screw driver
Heat exchanger
Cross flow fan
Screw

Advertisement

Table of Contents
loading

Table of Contents