Toshiba RAS-24J2KVG-UA Service Manual page 58

Table of Contents

Advertisement

10-4-3. Draining the Water
Holes are provided on the base plate of the
outdoor unit to ensure that the defrost water
produced during heating operations is drained off
efficiently. If a centralized drain is required when
installing the unit on a balcony or wall, follow the
steps below to drain off the water.
1.
Proceed with water-proofing by installing the
water-proof rubber caps in the 2 elongated holes
on the base plate of the outdoor unit. [How to install
the water-proof rubber caps]
1) Place four fingers into each cap, and insert
the caps into the water drain holes by pushing
them into place from the underside of the base plate.
2) Press down on the outer circumferences of the caps
to ensure that they have been inserted tightly.
(Water leaks may result if the caps have not
been inserted properly, if their outer circumferences
lift up or the caps catch on or wedge against
something.)
2. Install the drain nipple and a commercially available
Water-proof rubber caps
(supplied with the outdoor unit)
Base plate
Drain nipple
- 58 -
FILE NO. SVM-19002
drain hose (with16 mm inside diameter), and drain
off the water. (For the position where the drain nipple
is installed, refer to the installation diagram of the
indoor and outdoor units.)
• Check that the outdoor unit is horizontal, and route the
drain hose at a downward sloped angle while ensuring
that it is connected tautly.
Drain nipple
Base plate
Do not use ordinary garden hose, but one can
flatten and preven water from draining.
Commercially available
drain hose

Advertisement

Table of Contents
loading