Toshiba RAS-24J2KVG-UA Service Manual page 54

Table of Contents

Advertisement

<When the installation plate is directly mounted on
the wall>
1. Securely fit the installation plate onto the wall by
screwing it in the upper and lower parts to hook up
the indoor unit.
2. To mount the installation plate on a concrete wall
with anchor bolts, utilize the anchor bolt holes as
illustrated in the above figure.
3. Install the installation plate horizontally in the wall.
CAUTION
When installing the installation plate with a
mounting screw, do not use the anchor bolt hole.
Otherwise the unit may fall down and result in
personal injury and property damage.
Installation plate
<Keep horizontal direction>
Fig. 10-3-4
5 mm dia. hole
Clip anchor
(local parts)
Fig. 10-3-5
CAUTION
Failure to firmly install the unit may result in
personal injury and property damage if the unit falls.
• In case of block, brick, concrete or similar type
walls, make 5 mm dia. holes in the wall.
• Insert clip anchors for appropriate mounting screws
6 .
NOTE:
• Secure four corners and lower parts of the
installation plate with 4 to 6 mounting screws to
install it.
Anchor
bolt
Projection
15 mm or less
6
Mounting
screw
∅4 mm x 25 s s s s s
- 54 -
FILE NO. SVM-19002
10-3-3. Piping and drain hose installation
<Piping and Drain Hose Forming>
* Since dewing results in a machine trouble, make
sure to insulate both the connecting pipes. (Use
polyethylene foam as insulating material.)
Rear right
Rear left
Bottom left
Left
Bottom right
Right
Fig. 10-3-6
1. Die-cutting back body slit
Cut out the slit on the leftward or right side of the back
body for the left or right connection and the slit on the
bottom left or right side of the back body for the bottom
left or right connection with a pair of nippers.
2. Changing drain hose
For leftward connection, bottom-leftward connection
and rearleftward connection's piping, it is necessary to
change the drain hose and drain cap.
<How to remove the Drain hose>
The drain hose can be removed by removing the
screw securing the drain hose and then pulling out
the drain hose.
When removing the drain hose, be careful of any
sharp edges of steel plate. The edges can injuries.
To install the drain hose, insert the drain hose firmly
until the connection part contacts with heat insulator,
and the secure it with original screw.
Drain hose
Fig.
<How to remove the Drain Cap>
Clip the drain cap by needle-nose pliers and pull out.
Fig. 10-3-8
-3-7

Advertisement

Table of Contents
loading

Table of Contents