Toshiba RAS-24J2KVG-UA Service Manual page 22

Table of Contents

Advertisement

7.2 Operation Data
<Cooling>
Tempeature
Model name
condition(°C)
RAS-
Indoor
Outdoor
27/19
35/-
24J2KVG-E
24J2KVG-TR
24J2KVG-UA
24J2KVG-EE
<Heating>
Tempeature
Model name
condition(°C)
RAS-
Indoor
Outdoor
24J2KVG-E
20/-
7/6
24J2KVG-TR
24J2KVG-UA
24J2KVG-EE
NOTES :
1. Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent.
(Thermistor thermometer)
Heat exchanger
Standard
pipe temp.
pressure
P (MPa)
T1 (°C)
T2 (°C)
0.9 to 1.0 10 to 11
50 to 52
Heat exchanger
Standard
pipe temp.
pressure
P (MPa)
T1 (°C)
T2 (°C)
2.8 to 3.0
42 to 44
0 to 1
- 22 -
FILE NO. SVM-19002
Indoor
Outdoor Compressor
fan mode fan mode
High
High
Indoor
Outdoor Compressor
fan mode fan mode
High
High
Connecting
Piping
revolution
(rps)
(m)
82
7.5
Connecting
Piping
revolution
(m)
(rps)
85
7.5

Advertisement

Table of Contents
loading

Table of Contents