Download Print this page

Mitsubishi Electric FR-A820-04750-GF Instruction Manual page 79

Hide thumbs Also See for FR-A820-04750-GF:

Advertisement

• To use the inverter of FR-A820-01250(22K) or lower and FR-A840-00620(22K) or lower (IP20) outside of an enclosure in the environment of pollution
degree 2, fix a fan cover with fan cover fixing screws enclosed.
• On the input and output of the inverter, use cables of the type and size set forth in EN 60204 and IEC 60364-5-52.
• The operating capacity of the relay outputs (terminal symbols A1, B1, C1, A2, B2 and C2) should be 30 VDC, 0.3 A. (Relay output has basic isolation from
the inverter internal circuit.)
• Control circuit terminals on
page 4
• Environment (For the detail, refer to
LD, ND (initial setting), HD: 0 to +50°C
Surrounding air temperature
SLD: 0 to +40°C
Ambient humidity
95% RH or less
Maximum altitude
2500 m

For the installation at an altitude above 1000 m, consider a 3% reduction in the rated current per 500 m increase in altitude.
 Branch circuit protection
Class T, Class J, Class CC, or Class L fuse, or UL 489 Molded Case Circuit Breaker (MCCB) must be provided.
For the FR-A820 series, Class T, Class J, or Class CC fuse, or UL 489 Molded Case Circuit Breaker (MCCB) must be provided.
(Use a product which conforms to the EN or IEC Standard.)
00046
FR-A820-[]
(0.4K)
Rated fuse voltage (V)
240 V or more
Without power
factor improving
15
Fuse allowable
reactor
rating (A)
With power factor
15
improving reactor
Molded case circuit breaker (MCCB)
15
Maximum allowable rating (A)

00930
FR-A820-[]
(18.5K)
Rated fuse voltage (V)
240 V or more
Without power
factor improving
225
Fuse allowable
reactor
rating (A)
With power factor
200
improving reactor
Molded case circuit breaker (MCCB)
225
Maximum allowable rating (A)

00023
FR-A840-[]
(0.4K)
Rated fuse voltage (V)
500 V or more
Without power
factor improving
6
Fuse allowable
reactor
rating (A)
With power factor
6
improving reactor
Molded case circuit breaker (MCCB)
15
Maximum allowable rating (A)

00930
FR-A840-[]
(37K)
Rated fuse voltage (V)
500 V or more
Without power
factor improving
200
Fuse allowable
reactor
rating (A)
With power factor
175
improving reactor
Molded case circuit breaker (MCCB)
225
Maximum allowable rating (A)


Maximum allowable rating by US National Electrical Code. Exact size must be chosen for each installation.
Fan cover
fixing screw
Fan cover
Fan
FR-A820-00105(1.5K) to 00250(3.7K)
FR-A840-00083(2.2K), 00126(3.7K)
are safely isolated from the main circuit.
page
3.)
During operation

00077
00105
00167
00250
(0.75K)
(1.5K)
(2.2K)
(3.7K)
20
30
40
60
20
20
30
50
15
25
40
60
01250
01540
01870
02330
(22K)
(30K)
(37K)
(45K)
300
350
400
500
250
300
350
400
300
350
450
500
00038
00052
00083
00126
(0.75K)
(1.5K)
(2.2K)
(3.7K)
10
15
20
30
10
10
15
25
15
15
20
30
01160
01800
02160
02600
(45K)
(55K)
(75K)
(90K)
250
300
200
250
300
350
250
450
450
500
Fan cover
fixing screw
Fan cover
Fan
FR-A820-00340(5.5K) to 00250(22K)
FR-A840-00170(5.5K) to 00620(22K)
In storage
-20 to +65°C
95% RH or less
2500 m
00340
00490
00630
00770
(5.5K)
(7.5K)
(11K)
(15K)
80
150
175
200
70
125
150
200
80
110
150
190
03160
03800
04750
(55K)
(75K)
(90K)
500
500
600
700
700
900
1000
00170
00250
00310
00380
(5.5K)
(7.5K)
(11K)
(15K)
(18.5K)
40
70
80
90
110
35
60
70
90
100
40
60
70
90
100
03250
03610
04320
04810
(110K)
(132K)
(160K)
(185K)
400
500
600
700
800
During transportation
-20 to +65°C
95% RH or less
10000 m
00470
00620
00770
(22K)
(30K)
150
175
125
150
150
175
05470
06100
06830
(220K)
(250K)
(280K)
900
1000
Appendix
21

Advertisement

loading