Mitsubishi Electric FR-A820-04750-GF Instruction Manual page 111

Hide thumbs Also See for FR-A820-04750-GF:

Advertisement

Pr.
Name
263
Subtraction starting frequency
Power failure deceleration time
266
switchover frequency
374
Overspeed detection level
Frequency for maximum input
386
pulse
422
Position control gain
505
Speed setting reference
Current average value monitor
557
signal output reference current
Regeneration avoidance
665
frequency gain
820
Speed control P gain 1
821
Speed control integral time 1
Torque control P gain 1 (current
824
loop proportional gain)
Torque control integral time 1
825
(current loop integral time)
870
Speed detection hysteresis
Regeneration avoidance
885
compensation frequency limit
value
Energy saving monitor reference
893
(motor capacity)
C14
Terminal 1 gain frequency
(918)
(speed)
Per-unit speed control reference
1121
frequency
*1
When a value other than "9999" is set, the set value is not changed.
*2
The rated motor rotations per minute (frequency), maximum motor rotations per minute (frequency), number of motor poles, and rated
motor current are as follows.
Rated motor rotations per
minute (frequency)
Maximum motor rotations per
minute (frequency)
Number of motor poles
Rated motor current
NOTE
• When the motor parameter initialization is performed with the setting in units of rotations per minute (Pr.998 =
"3044"), the parameters not listed in the table and the monitor items are also set and displayed in rotations per
minute.
 List of the target parameters for the motor parameter initialization
(other than EM-A)
• The settings in Pr.10, Pr.422, and Pr.665 are changed to the settings shown in the following table by selecting
a motor other than EM-A with the IPM initialization on the operation panel or with Pr.998 PM parameter
initialization. For other parameters whose settings are to be changed, refer to the Instruction Manual (Detailed).
Pr.
Name
DC injection brake operation
10
frequency
422
Position control gain
Regeneration avoidance
665
frequency gain
*1
The setting value is converted from frequency to rotations per minute. (It differs according to the number of motor poles.)
Induction
motor
Pr.998 = "0
(initial value)"
FM
CA
60 Hz
50 Hz
60 Hz
50 Hz
9999
60 Hz
50 Hz
-1
25 s
60 Hz
50 Hz
Inverter
rated current
100%
60%
0.333 s
100%
5 ms
0 Hz
6 Hz
Inverter rated
capacity
60 Hz
50 Hz
120 Hz
Item
3000 r/min (100 Hz)
4000 r/min (133.33 Hz)
4
0.75kW: 3.3 A, 1.5kW: 6.1 A, 2.2kW: 9.3 A, 3.7kW: 16.5 A, 5.5kW: 22.0 A, 7.5kW: 31.0 A
Induction
motor
Pr.998 = "0
(initial value)"
FM
CA
3 Hz
-1
25 s
100%
PM motor (setting in
rotations per minute)
Pr.998 = "3044" (EM-A)
Rated motor rotations per
*2
minute
Rated motor rotations per
*2
minute
Maximum motor rotations
*2
per minute × 115%
Rated motor rotations per
*2
minute
-1
20 s
*2
Rated motor frequency
*2
Rated motor current
80%
30%
0.333 s
150%
6.7 ms
Rated motor rotations per
*2
minute × 0.5%
Rated motor rotations per
*2
minute × 6%
Motor capacity (Pr.80)
Rated motor rotations per
*2
minute
Maximum motor rotations
*2
per minute
0.75kW
PM motor (setting in
rotations per minute)
Pr.998 = "3003" (MM-CF)
Pr.998 = "3103" (MM-CF)
Pr.998 = "8009, 9009"
(other than EM-A/MM-
CF)
*1
3 Hz
3 Hz
-1
25 s
100%
4
PM motor (setting in
frequencies)
Pr.998 = "3144" (EM-A)
*2
Rated motor frequency
*2
Rated motor frequency
Maximum motor frequency ×
*2
115%
*2
Rated motor frequency
Rated motor frequency ×
*2
0.5%
Rated motor frequency ×
*2
6%
*2
Rated motor frequency
*2
Maximum motor frequency
1.5kW or higher
3000 r/min (150 Hz)
4000 r/min (200 Hz)
6
PM motor (setting in
frequencies)
Pr.998 =
Pr.998 = "8109, 9109"
(other than EM-A/MM-
CF)
1 r/min
1 s
0.1%
BCN-C22005-1008
Setting increments
Pr.998 =
Pr.998 =
"3044"
"0, 3144"
1 r/min
0.01 Hz
1 r/min
0.01 Hz
1 r/min
0.01 Hz
1 r/min
0.01 Hz
-1
1 s
0.01 Hz
0.01 A
0.1%
1%
0.001 s
1%
0.1 ms
1 r/min
0.01 Hz
1 r/min
0.01 Hz
0.01 kW
1 r/min
0.01 Hz
1 r/min
0.01 Hz
Setting increments
Pr.998 = "0,
"3003,
3103, 8109,
8009,
9109"
9009"
0.01 Hz
-1