Note
If the DI/DQ interfaces X122, X132 and X142 are operated partially as DI and partially as DQ
(mixed operation), then the DI must be operated with the same power supply as the NCU
module power supply X124.
This applies to:
• 6FC5317-5AA00-0AA0, hardware versions FS: A to E
• 6FC5317-5AA00-0AA1, is not affected.
Pin assignment
Table 8-18
Pin
1
2
3
4
5
6
7
8
9
NCU 1750
Equipment Manual, 10/2023, A5E45627807B AH
X122 digital inputs/outputs
Signal
Signal
Meaning
name
type
DI0
I
Digital input 0
Input ON/OFF1 infeed (if one infeed with a DRIVE-CLiQ
connection is operated at the NCU)
DI1
I
Digital input 1
Input 2. Operating condition OFF3 drives
"OFF3 – rapid stop"
Braking with a configurable OFF3 ramp (p1135, p1136,
p1137); thereafter, pulse suppression and switching on
inhibited. The drive stops controlled. The braking re‐
sponse can be set separately for each SERVO.
DI2
I
Digital input 2
Selection safe standstill group 1
SH/SBC - Group 1 SINAMICS Safety Integrated (SH =
p9601 release)
DI3
I
Digital input 3
Selection safe standstill group 2
SH/SBC - Group 2 SINAMICS Safety Integrated (SH =
p9601 release)
DI16
I
Digital input 16
Freely available
DI17
I
Digital input 17
Freely available
G1
GND
Ground for DI0 - DI3, DI16, DI17 (isolated with respect
to M)
M
GND
Ground for DI8 - DI11
DI/DO8
B
Digital input/output 8 (rapid input)
Status safe standstill group 1
SH/SBC - Group 1
SINAMICS Safety Integrated
Connecting
8.10 Digital inputs/outputs
Default set‐
ting
x
x
---
---
---
---
 
 
---
83