Siemens SINUMERIK ONE 6FC5317-5AA00-0AA0 Equipment Manual page 143

Table of Contents

Advertisement

Power loss
Output power X111, X222, X333:
Mechanical data
Dimensions WxHxD
Weight, approx.
Pollution degree
Heat dissipation/cooling
Condensation
Limitation of relative air humidity at
25 °C
Air pressure
Derating
Ambient temperature:
Storage
Shock load during transport (in
transport packaging)
For detailed technical data relating to the inputs and outputs, see the "Connecting" chapter.
X111, X222 and X333 pin assignment (Page 126)
Analog X3 inputs/outputs (Page 131)
NCU 1750
Equipment Manual, 10/2023, A5E45627807B AH
Resistor
Pilot duty
Tungsten
Storage
Transport
Operation
12.2 PP 72/48D PN and PP 72/48D 2/2A PN
 
24 V DC; 0.25 A/channel; 4 A/terminal
24 V DC; 0.25 A/channel; 4 A/terminal
150 x 300 x 35 mm
Open-circuit ventilation
Not permitted
5 to 95% (without condensation)
5 to 90% (with condensation)
106 to 92 kPa or
0 to 1000 m above mean sea level
At installation altitudes of more than 1000 to 4000 m above mean
sea level, the upper temperature limit must be reduced by
3.5 °C / 500 m.
1M2 (in product package); 1.5 mm; 0.5 g
Free-fall ≤ 1 m
Connectable components
18 W
24 V; 5 W
0.9 kg
2
 
-40 to 70 °C
-40 to 70 °C
   0 to 55 °C
143

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik one ncu 1750Sinumerik one 6fc5317-5aa00-0aa1

Table of Contents