Connectable components
12.2 PP 72/48D PN and PP 72/48D 2/2A PN
Analog inputs
Table 12-30
16-bit value (hex.)
Overflow
Overrange
0x19B5
0x0CDA
0x066D
0x0000
0xF993
0xF326
0xE64B
Underrange
Underflow
Table 12-31
16-bit value (hex.)
Overflow
Overrange
0x1999
0x0CCC
0x0000
0xF333
0xE666
Underrange
Underflow
Table 12-32
16-bit value (hex.)
Overflow
0x0A28
0x03E8
0x01F4
0x0000
0xFE0C
0xFC18
0xF830
Underflow
136
Measured values in the voltage measurement operating mode
16-bit value (dec.)
6581
3291
1645
0
-1645
-3291
-6581
Measured values in the current measurement operating mode
16-bit value (dec.)
6553
3277
0
-3277
-6553
Measured values in the "temperature measurement" operating mode
16-bit value (dec.)
2590
1000
500
0.0
-500
-1000
-2000
Factor
-
-
 
 
 
0.00152
-
-
Factor
-
-
 
 
0.00305
-
-
Factor
 
 
 
0.1
 
Equipment Manual, 10/2023, A5E45627807B AH
Voltage value [V]
Deactivation
up to 11.75 V
10 V
5 V
2.5 V
0 V
-2.5 V
-5 V
-10 V
Up to -11.75 V
Deactivation
Current value [mA]
Deactivation
up to 23.5 mA
20 mA
10 mA
0 mA
-10 mA
-20 mA
up to -23.5 mA
Deactivation
Temperature value [°C]
 
259 °C
100 °C
50 °C
0 °C
-50 °C
-100 °C
-200 °C
 
NCU 1750