DEHUMIDIFIER
refrigerant (i.e. special cylinders for the recovery of refrigerant). Cylinders shall
be complete with pressure-relief valve and associated shut-off valves in good
working order. Empty recovery cylinders are evacuated and, if possible, cooled
before recovery occurs.
The recovery equipment shall be in good working order with a set of instructions
concerning the equipment that is at hand and shall be suitable for the
recovery of all appropriate refrigerants including, when applicable, fl ammable
refrigerants. In addition, a set of calibrated weighing scales shall be available
and in good working order. Hoses shall be complete with leak-free disconnect
couplings and in good condition. Before using the recovery machine, check
that it is in satisfactory working order, has been properly maintained and that
any associated electrical components are sealed to prevent ignition in the
event of a refrigerant release. Consult manufacturer if in doubt.
The recovered refrigerant shall be returned to the refrigerant supplier in the
correct recovery cylinder, and the relevant waste transfer note arranged. Do
not mix refrigerants in recovery units and especially not in cylinders.
If compressors or compressor oils are to be removed, ensure that they
have been evacuated to an acceptable level to make certain that fl ammable
refrigerant does not remain within the lubricant. The evacuation process shall
be carried out prior to returning the compressor to the suppliers. Only electric
heating to the compressor body shall be employed to accelerate this process.
When oil is drained from a system, it shall be carried out safely.
Certifi cate of compliance CE
The importer G.E. DIMITRIOU SA declares that this product complies with
the general requirements pursuant to the following European Directives:
LVD: 2014/35/EU
EMC: 2014/30/EU
RoHS: (EU)2015/863
Therefore the product has been marked with the
Declaration of Conformity has been issued and is available to the
competent authorities regulating the market.