3. When the user changes the set mode, set temperature and set fan speed to
make them different from the state in memory, start the time counting; when
the timer expires, restore the set mode, set temperature and set fan speed
to the memory. (Only restore the set mode, set temperature, set fan speed,
do not change the switch state). When the switch state changes, the original
setting function will be restored if it is not cancelled.
4. If the user wants to update the memorised fixed mode, set temperature and
set fan speed status, it is necessary to turn off the function and then turn it
on again.
5. When the function of Auto Restore to original setting is enabled, if the weekly
timer function has been turned on, a pop-up window will remind the user that
there is a conflict of functions. It is necessary to confirm that weekly timer
function is turned off. If the user chooses to confirm, the weekly timer will
be turned off and continue to enter the automatic recovery setting interface,
select Cancel Return directly.
6. When the weekly timer function is turned on, if the Auto Restore function has
been turned on, a pop-up window will remind the user of the function conflict.
It is necessary to confirm that the timer recovery original setting function is
turned off. If the user chooses to confirm, the Auto Restore will be turned off
and continue to enter the weekly timer setting interface, select Cancel Return
directly.