Electrical Data - York ZF210 Instruction Manual

Hide thumbs Also See for ZF210:
Table of Contents

Advertisement

Table 8: Electrical Data
ZF180-300 - Standard Drive Without Powered Convenience Outlet
Compressors
Size
Volt
(Tons)
RLA
C1
C2
208-3-60 25.0
25.0
230-3-60 25.0
25.0
180
(15)
460-3-60 12.8
12.8
575-3-60 9.6
9.6
208-3-60 30.7
30.7
230-3-60 30.7
30.7
210
(17.5)
460-3-60 14.3
14.3
575-3-60 12.9
12.9
208-3-60 33.3
33.3
230-3-60 33.3
33.3
240
(20)
460-3-60 17.9
17.9
575-3-60 12.8
12.8
Johnson Controls Unitary Products
OD Fan
Motors
(each)
(each)
LRA
MCC
FLA
C1
C2
C1
C2
164
164
39
39
4.5
164
164
39
39
4.3
100
100
20
20
2.2
78
78
15
15
1.7
203
203
43
43
4.5
203
203
43
43
4.3
98
98
20
20
2.2
84
84
18
18
1.7
239
239
52
52
4.5
239
239
52
52
4.3
125
125
28
28
2.2
80
80
20
20
1.7
Supply
Pwr
Blower
Conv
Electric Heat Option
Motor
Outlet
FLA
FLA
Model
kW
None
--
E18
13.5
15.4
0.0
E36
27
E54
40.6
E72
54.1
None
--
E18
18.0
14.4
0.0
E36
36.0
E54
54.0
E72
72.0
None
--
E18
18.0
7.2
0.0
E36
36.0
E54
54.0
E72
72.0
None
--
E18
18.0
5.9
0.0
E36
36.0
E54
54.0
E72
72.0
None
--
E18
13.5
15.4
0.0
E36
27.0
E54
40.6
E72
54.1
None
--
E18
18.0
14.4
0.0
E36
36.0
E54
54.0
E72
72.0
None
--
E18
18.0
7.2
0.0
E36
36.0
E54
54.0
E72
72.0
0
--
E18
18.0
5.9
0.0
E36
36.0
E54
54.0
E72
72.0
None
--
E18
13.5
15.4
0.0
E36
27
E54
40.6
E72
54.1
None
--
E18
18.0
14.4
0.0
E36
36.0
E54
54.0
E72
72.0
None
--
E18
18.0
7.2
0.0
E36
36.0
E54
54.0
E72
72.0
None
--
E18
18.0
5.9
0.0
E36
36.0
E54
54.0
E72
72.0
1088917-YIM-B-1014
Max Fuse
1
MCA
Breaker
(Amps)
Stages
Amps
--
--
80.7
1
37.5
80.7
2
74.9
112.9
2
112.7
160.1
2
150.2
169.4
--
--
79.3
1
43.3
79.3
2
86.6
126.3
2
129.9
147.9
2
173.2
191.2
--
--
40.4
1
21.7
40.4
2
43.3
63.1
2
65.0
74.0
2
86.6
95.6
--
--
30.9
1
17.3
30.9
2
34.6
50.7
2
52.0
59.3
2
69.3
76.7
--
--
93.5
1
37.5
93.5
2
74.9
112.9
2
112.7
160.1
2
150.2
169.4
--
--
92.1
1
43.3
92.1
2
86.6
126.3
2
129.9
147.9
2
173.2
191.2
--
--
43.8
1
21.7
43.8
2
43.3
63.1
2
65.0
74.0
2
86.6
95.6
--
--
38.3
1
17.3
38.3
2
34.6
50.7
2
52.0
59.3
2
69.3
76.7
--
--
99.3
1
37.5
99.3
2
74.9
112.9
2
112.7
160.1
2
150.2
169.4
--
--
97.9
1
43.3
97.9
2
86.6
126.3
2
129.9
147.9
2
173.2
191.2
--
--
51.9
1
21.7
51.9
2
43.3
63.1
2
65.0
74.0
2
86.6
95.6
--
--
38.1
1
17.3
38.1
2
34.6
50.7
2
52.0
59.3
2
69.3
76.7
2
/
3
Size
(Amps)
100
100
125
175
200
100
100
150
175
225
50
50
70
90
110
40
40
60
70
90
110
110
125
175
200
110
110
150
175
225
50
50
70
90
110
50
50
60
70
90
125
125
125
175
200
125
125
150
175
225
60
60
70
90
110
50
50
60
70
90
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zf180Zf seriesZf240Zf300