3-7-1, Memory Scan; 3-7-2, Program Scan; Scan Speed - Kenwood TS-440S Instruction Manual

Hf transceiver
Hide thumbs Also See for TS-440S:
Table of Contents

Advertisement

In example
1 we want to scan only Group 2, so we
would press the 2 key. In example 2 we want to scan
Group 1 and Group 2, so we would press the 1 key
and then the 2 key.
Example
1
Group 2
ia!
Example 2
Group 1
Group 2
cHes
oHo
cHIa
CHSO.
cH39
4, You can stop scanning, or resume scan using the
same
methods
described above for the entire
memory scan.
3-7-2.
Program scan
Two programmable
scan ranges are provided on the
TS-440S transceiver. PG.S-1
(Program Scan range 1}
utilizes memory channels 06 and 07 to specify the up-
per and lower scan limits. PG.S-2 (Program Scan range
2) utilizes memory channels 08 and O9 to specify the
upper and lower scan limits.
To initiate PG.S
1, Press the VFO/M
key to select VFO
operation.
NR . Press and hold the SCAN key.
@ . To initiate PG.S 1 press the 6 key, and then release
both the 6 and the SCAN keys. Scan will begin on
the frequency
programmed
in memory
channel
number 6 and proceed in 10 Hz steps to the upper
jimit stored in memory
channel
7, then return to
channel 6 and begin again.
Ge POS-I—,
HE
PAS:
CH?
ra S18 00 14.0000
oo
Le ---aad
&
. Toinitiate PG.S 2 press the 8 key, and then release
both the 8 and the SCAN key. Scan will proceed
in the limits specified in memory
channels 8 and
9, just as for PG.S 1.
r——PGS-2—,
ons
CHa
14,200.00
14, 320,00
g
. if you want to scan both ranges PG.S 4 and PG.S
2, press the 6 and then the 8 key while holding the
SCAN key down, and then release the SCAN key.
Scan will proceed thru the limits in memory chan-
nels 6 and 7, thru the limits in memory
channels
8 and 9, and then return to begin the process again.
—PGs-2—
cH
ons
a
To stop scanning
press the PTT switch,
or the
CLEAR key. Pressing the SCAN key allows scan to
resume from the point you stopped.
Note:
The TS-440S microprocessor remembers the various
scan parameters that you have specified and will fal-
low whatever
you
have entered
the next time you
press the SCAN
key.
Example
1: Memory
mode
Previously
programmed
memory
scan
data was to scan channels 20-29 and
40-49.
To scan
this same
range again simply
press the SCAN
key.
Example 2: VFO mode
Previously entered program scan data
was to scan both PG.S1 and PG.S2.
To initiate program scan over these two.
ranges again simply press the SCAN key.
The TS-4408 will continue to execute scan according
to the above parameters until you manually change the
information. This saves a lot of key strokes if you al-
ways scan the same ranges, etc.
3-7-3.
Scan speed
Two scan speeds are available with the TS-440S.
To change the speed press the SCAN key after you
have initiated scan. You will be able to taggle between
fast and slow each time you press the key.
Note:
The scan step size depends upon the mode that has
been selected for SSB, CW and AFSK the step size is
10 Hz, for FM and AM the step size is 100 Hz.
3-7-4, Memory channel lockout
This transceiver has a memory channel lockout func-
tion which allows you to temporarily skip unwanted
memory
channels during memory scan.
. Press the VFO/M
key to enter the memory mode.
2. Select the memory channel that you want to skip
using the numeric keypad, the TUNING knob, or the
UP/DOWN
microphone or BAND
switches.
. Press the CLEAR switch.
wo
mom
5
fu
PIE A
esd
Tea
|
- . A decimal point will appear in the M.CH display to
indicate that the channel will be skipped.
wen
aus
76 7
ea
itl
5
|
a . To cancel the lockout, select the desired channel
and then press the CLEAR
switch. The decimal
point will go out indicating that the channel will
again be scanned.
2th
i7Sd
|

Advertisement

Table of Contents
loading