m Canceling Automatic Offset
Automatic Offset can be canceled as described below:
1 Press [CALL] + POWER
ON to enter Menu
Set-up.
2 Turn the ENC/SQL control to select Menu No. 07.
e The current Automatic Offset status appears.
e
The default is "ON" for TH-22 versions sold in
the U.S.A., Canada and Europe.
3 Press [CALL] to select "OFF" or "ON".
e OFF: Cancels Automatic Offset.
e ON:
Restores Automatic Offset.
4 Press any key ether than [CALL], [LAMP], or
[MONI] to exit Menu Set-up.
Note:
After turning ON Automatic Offset again, or after
transferring memory channel contents to the VFO, the
feature resumes functioning when a new frequency is
selected.
SELECTING OFFSET VALUES
MANUALLY
To change the amount of offset, use the following
procedure:
1 Press [F] (1s), [REV].
2 Turn the ENC/SQL control to select the desired value.
« The values range from 0.00 MHz to 99.95 MHz in
50 kHz steps.
3 Press any key other than [MONI] or [LAMP] to store
the selected value.
e The previous mode is restored.
Remember the following points before altering the offset:
e
lItis not possible to set different offset values for the
VFO and memory channels.
29