8.2

Parameter related to encoder pulse dividing output

Pr.
Pr.
group
Control terminal option-
863
M600
Encoder pulse division
ratio
• Division waveform by division ratio
Both ON-OFF width is division times. (50% duty)
• Pulse waveform example at 1000 pulse input when Pr.863 = "2"
NOTE
• Control of forward rotation/reverse rotation by phase difference between A phase and B phase.
When A phase is 90° advanced as compared to B phase: forward rotation
When A phase is 90° behind as compared to B phase: reverse rotation
68
ENCODER PULSE DIVIDING OUTPUT
Initial
Name
value
1
Division ratio
A-phases
1/1
B-phases
Division ratio
A-phases
1/2
B-phases
Setting
range
The encoder pulse signal at the motor end can be divided in
division ratio set in Pr.863 and output.
1 to 32767
Use this parameter to make the response of the machine to be
input slower, etc.
2 divisions
Description
(1000 pulses)
(500 pulses)